32DSSK03.B
2 - 6
MAIN CIRCUIT BREAKER
Refer to
Figure 2-8
. The main circuit breaker is located in the vehicle engine compartment
and is used to interrupt electrical power to the lift electrical system when a major short circuit
occurs. In such an event, the circuit breaker reset tab will “flip-down”. If pressing reset tab
back up (as shown by arrow) and releasing it does not reset power, do not press and hold
tab. Contact a Ricon authorized dealer for repair.
Optional Door Operator Circuit Breaker
Refer to
Figure 2-7
. The circuit breaker for optional door operator is located on the hydraulic
pump assembly. In the event of a short circuit in the door operator, the circuit breaker button
will “pop-out”. If pressing and releasing button does not reset power, do not press and hold.
Contact a Ricon authorized dealer for repair. Refer to appropriate Power Door Operator ser-
vice manual for a detailed description.
Control System Circuit Breaker
Refer to
Figure 2-7
. The Control System Circuit Breaker is located on the hydraulic pump as-
sembly. In the event of a short circuit in the control system, the circuit breaker button will
“pop-out”. If pressing and releasing button does not reset power, do not press and hold.
Contact a Ricon authorized dealer for repair.
Pump Solenoid LED Status Indicator
Refer to
Figure 2-7
. A second pump solenoid is installed next to the original pump solenoid
and a green LED is located between the 8A and 30A circuit breakers. The LED monitors the
condition of the two solenoids. The LED is on when the pump is operating, and off when the
pump is off. For more information on this LED refer to the service manual 32DSSK04.
BRIDGEPLATE LOAD SENSOR
Refer to Figure 1-1 and Table 1-1 in Chapter 1 for the location of the switch that detects the
presence of a load on the bridgeplate. When the sensor switch detects that an object is present
on the bridgeplate it inhibits lowering of the platform. This protects the passenger from possible
injury when the bridgeplate rises. It also protects the bridgeplate from damage, which could later
interfere with proper operation of the lift.
RESET
TAB