Service Call
SM
6-7
M154/M155/M174/M175/A0A7/M287/M0BB
T
ro
ub
le
s
ho
ot
in
g
542
Fuser reload error
This SC occurs, if any of the following conditions are met:
In a 100V power supply environment:
1. The fusing temperature increased 6 degrees C or less for 5 times
consecutively within 1.5 seconds.
2. The fusing temperature did not reach 45 degrees C within 11 seconds after the
fusing lamp turned ON.
3. The fusing temperature did not reach the reload temperature within 35 seconds
in a normal/high temperature operational environment, or 55 seconds in a low
temperature operational environment.
In a 200V power supply environment:
1. The fusing temperature increased 9 degrees C or less for 5 times
consecutively within 1.5 seconds.
2. The fusing temperature did not reach 45 degrees C within 11 seconds after the
fusing lamp turned ON.
3. The fusing temperature did not reach the reload temperature within 35 seconds
in a normal/high temperature operational environment, or 50 seconds in a low
temperature operational environment.
Disconnected or defective thermistor
Incorrect input power supply detected at the main power socket
Heater defective or thermostat circuit disconnected
Important
To resolve the SC, perform "Reset Fusing Unit SC" after solving the problem,
or the system will continue to display the SC.
543
High temperature error (Soft)
The detected temperature stays at 235°C for 1 second, and this
consecutively occurs 10 times.
Defective Main board
Defective PSU
1. Replace the Main board
2. Replace the PSU
Execute "Reset Fusing Unit SC" to recover the machine after completing
the recovery procedure. Otherwise, the machine continues to issue this
SC code and cannot be operated.
Summary of Contents for SP 310DN
Page 1: ...M154 M155 M174 M175 A0A7 M287 M0BB SERVICE MANUAL...
Page 10: ......
Page 15: ...PRODUCT INFORMATION REVISION HISTORY Page Date Added Updated New None...
Page 16: ......
Page 20: ......
Page 21: ...INSTALLATION REVISION HISTORY Page Date Added Updated New None...
Page 22: ......
Page 26: ......
Page 27: ...PREVENTIVE MAINTENANCE REVISION HISTORY Page Date Added Updated New None...
Page 28: ......
Page 36: ......
Page 37: ...REPLACEMENT AND ADJUSTMENT REVISION HISTORY Page Date Added Updated New None...
Page 38: ......
Page 47: ...Exterior Covers SM 4 9 M154 M155 M174 M175 A0A7 M287 M0BB Replacement and Adjustment...
Page 84: ...Electrical Components M154 M155 M174 M175 A0A7 M287 M0BB 4 46 SM 20 PSU A x 4 x 1...
Page 92: ......
Page 93: ...SERVICE TABLES REVISION HISTORY Page Date Added Updated New None...
Page 94: ......
Page 136: ......
Page 137: ...TROUBLESHOOTING REVISION HISTORY Page Date Added Updated New None...
Page 138: ......
Page 159: ...ENERGY SAVE REVISION HISTORY Page Date Added Updated New None...
Page 160: ......
Page 167: ...M154 M155 M174 M175 A0A7 M287 M0BB SERVICE MANUAL APPENDICES...
Page 168: ......
Page 170: ......
Page 171: ...APPENDIX SPECIFICATIONS REVISION HISTORY Page Date Added Updated New None...
Page 172: ......
Page 178: ......
Page 180: ......