T
echnical
B
ulletin
PAGE: 2/5
Model:
Vacuum Feed LCIT
Date:
28-Oct-15
No.:
RD777004
SOLUTION
Apply the skew adjustment plates under the connection pins on the mainframe following
the procedure described in this document, in order to adjust the angle with which the LCIT
is connected to the mainframe.
8 adjustment plates come with the Vacuum Feed LCIT. Adding 1 adjustment plate will
correct approx 0.25mm/100mm of skew. Up to 4 plates can be inserted under the pin,
which means approx 1.0mm/100mm of skew can be corrected.
You can also procure the plate and screw as a service part to fasten it.
D7771116
ADJUSTING PLATE:BRACKET:COUPLING
09545014N
SCREW - M5X14
Procedure
1. Register the banner paper in use as a custom paper type.
2.
Only Andromeda:
Change 013: [Deactivate Image Position Adjustment]
to “ON” to
turn off the image position adjustment.
NOTE: It is turned off in Leo by default.
3. Print trim patterns to check the skew amount with the following procedure.
3-1. Enter SP mode and select [14: Trimming Area] in SP 2-109-003 (Test Pattern -
Pattern Selection).
3-2. Print 3 sheets of the test pattern.
3-3. Check the skew direction and measure the distance A and B.