T
echnical
B
ulletin
PAGE: 1/1
Reissued: 09-Oct-01
Model:
Model K-P1
Date:
15-May-01
No.:
RG058005b
RTB Update
The items in bold italics have been added.
Subject:
NIB Firmware History
Prepared by:
K. Misugi
From:
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Other ( )
Printer NIB firmware history for the Kir-P1 (G058/G056 model)
Part Number
Version
Production
G0585910G
1.54
September, ’01 production
G0585910F
1.53
June, ’01 production
G0585910E
1.51
April, ’01 production
G0585910D
1.49
February ’01 production
G0585910C
1.48
January ’01 production
G0585910B
1.47
December ’00 production
G0585910A
1.46
First mass production
Note:
The above firmware is being used in USA, Europe, and Asia models.
Descriptions
Version
Firmware modified to correct the following:
1. When using Signature level 2 on a NetWare Server, the printer does not
connect to the NetWare Server.
2. When printing out using a CICS application from an IBM mainframe (e.g.
AS/390), the printer is only able to output one job due to the lpd protocol that is
unique to CICS.
3. When 50 or more lpq/lprm commands (w/arguments) are executed from the
time the printer is turned on, the lpd process at the printer side is interrupted
and the job is not printed out.
1.54