Image Problems
Overview
Image problems can occur at regular intervals [A] due to the different circumferences of rollers in the
machine and inside the AIO.
Diameter (mm)
Interval (mm)
Component
9.5
30
Charge Roller (AIO)
12
27
Development roller (AIO)
14.6
44
Relay roller
14.2
44.6
Exit Roller
12.14
38
Transfer roller
25.06
78.7
Fusing roller
24
75
Drum (AIO)