222
GR-C1 Training
Slide 222
2. Energy Saving
2.3 Energy Save Effectiveness – 2
(1) At the start of the measurement period, read the values of
SP 8941:001-005 (Machine Status), measured in minutes.
(2) At the end of the measurement period,read the values of
SP 8941:001-005 (Machine Status), measured in minutes.
(3) Find the amount of time spent in each mode.
(Subtract the earlier measurement from the later
measurement and convert the result to hours.)
(4) Power consumption figures for each model are acquired
from “Publication System of MSDS_&_PEI (PRODUCT
ENVIRONMENT INFORMATION)” database.
Example:
1.4W (SP model)
1.7W (SPF model)
Off/Sleep mode
60W
Ready mode
600W
Operating mode
Power consumption:
Mode/condition
No additional notes