2.Replacement and Adjustment
59
15.
Execute SP1912-002 (CIS Image Position Adjustment: Normal Paper).
This sets the CIS for operation with standard copy paper.
16.
Exit the SP mode.
17.
Select [User Tools]> [Adjust Settings for Operators].
18.
Once again execute "0111-4 to -7" (CIS Image Position Adjustment: Feed Setting) and reset the
values for Trays 4, 5, 6, and 7 to "On".
Double Feed Problem With the LCT
If double feed occurs several times when paper is fed from the LCT, try changing the upper limit of the
paper stack in the tray
Changing the upper limit can improve paper separation.
1.
Remove the paper feed unit of the LCT unit (
2.
Loosen the screw on the lift sensor bracket [A].
3.
Move the bracket 0.7 mm in the arrow direction as shown below.