1.Replacement and Adjustment
24
4.
Remove the solenoid.
Re-installation
When re-installing the solenoid, make sure that the arm of the solenoid is positioned above and in
contact with the plate of the pick-up roller shaft below.
To confirm correct installation, manually move the solenoid plunger to the left and right. When the
solenoid plunger is moved, the pick-up roller should move up and down smoothly.
Bypass Tray PCB
1.
Remove the rear cover. (
2.
Disconnect the connectors on the board.
3.
Remove the board.
Two rivets secure the lower edge of the board.