72
Ricoh Co. Ltd.
http://www.ricoh.com/
B245-62 / PD-C4
Slide 72
Toner Density Control 5
Toner supply motor on time in
fixed control mode
The toner supply motor on
time is specified by the
setting of SP 2925, and does
not vary.
The default setting is 200 ms
for each copy. The toner
supply motor on time for
each value of SP 2925 is
shown in the table to the
right.
Effective only if SP 2921 is
set to 3.
Not supplied
7
Continuously
6
16t
5
12t
4
8t
3
4t
2
2t
1
t
0
Motor On Time
(t = 200 ms)
Value of
SP2925
No additional notes.