SP Modes – Symptom Troubleshooting 1
SP 1103: Fusing idling enable/disable
Enable if fusing on the first two copies is
incomplete
SP 1108: Fusing temperature control cycle
Increase if the user complains about flickering
room lights. However, fusing lamp errors may not
be detected.
SP 1903: Feed clutch boost
Increase the value if jams occur when feed
restarts after registration.
(Bypass tray only)