Fan RPM calibration
After replacing the main board, blower, or updating the firmware, "Fan RPM Calibration" should be
done.
1.
While pressing the "Power" button, plug in the power cord.
2.
When the "Power LED" flashes red, release the "Power" button.
3.
After 3 to 5 seconds, the projector will power on.
4.
After the logo disappears, the message "Warning Factory Fan RPM Calculation now,
please wait...." will be shown on the screen.
5.
After 70 seconds, please get into Service Mode to check "Factory Blower RPM".
6.
The value of "Factory Blower RPM" should be from 2880 to 4320rpm.
If the "Factory Blower RPM" value does not appear in Service Mode, please repeat the step again.
3. Replacement and Adjustment
42
3
Summary of Contents for Antares-PJ1 Series
Page 1: ...Model Antares PJ1 Machine Codes Y020 Y021 Y022 Field Service Manual 26 August 2011...
Page 2: ......
Page 10: ...8...
Page 14: ...1 Product Information 12 1...
Page 18: ...2 Installation 16 2...
Page 57: ...6 Click Next 7 Click Next 8 Click Next The program is being installed Firmware Update 55 4...
Page 66: ...4 System Maintenance 64 4...
Page 69: ...Main Procedures Main Procedures 67 5...
Page 70: ...A No Power Troubleshooting 5 Troubleshooting 68 5...
Page 72: ...If temp LED flashes 5 Troubleshooting 70 5...
Page 73: ...If lamp LED lights Main Procedures 71 5...
Page 74: ...If lamp LED flashes 5 Troubleshooting 72 5...
Page 75: ...Only power LED light red Main Procedures 73 5...
Page 76: ...C Image Troubleshooting 1 1 Does the PC image show on the screen 5 Troubleshooting 74 5...
Page 77: ...1 2 Does video image show on the screen Main Procedures 75 5...
Page 78: ...1 3 Does HDMI image show on the screen 5 Troubleshooting 76 5...
Page 79: ...1 4 Is audio output normal Main Procedures 77 5...
Page 80: ...1 5 Is focus ok 5 Troubleshooting 78 5...
Page 81: ...1 6 Is color ok Main Procedures 79 5...
Page 82: ...1 7 Have line bar 5 Troubleshooting 80 5...
Page 83: ...1 8 Is there noise in the image Main Procedures 81 5...
Page 84: ...1 9 Is uniformity ok 5 Troubleshooting 82 5...
Page 85: ...D Remote Control Troubleshooting Main Procedures 83 5...
Page 86: ...5 Troubleshooting 84 5...
Page 87: ...Model Antares PJ1 Machine Codes Y0020 Y021 Y022 Appendices 24 October 2011...
Page 88: ......
Page 90: ...2...