Service Call
Summary
Level
Definition
Reset Procedure
A
To prevent damage to the machine, the main machine
cannot be operated until the SC has been reset by a
service representative (see the note below).
Enter SP mode, go into
SP5-810-001, press [Execute],
and turn the main power switch
off and on.
B
SCs that disable only the features that use the defective
item. Although these SCs are not shown to the user
under normal conditions, they are displayed on the
operation panel only when the defective feature is
selected.
Turn the main power switch off
and on.
C
The SC history is updated. The machine can be
operated as usual.
The SC will not be displayed.
Only the SC history is updated.
D
Turning the main power switch off then on resets SCs
displayed on the operation panel. These are re-
displayed if the error occurs again.
Turn the main power switch off
and on.
When a Level “D” SC code occurs
When a Level D SC occurs, a screen opens on the operation panel to tell the operator:
• An error occurred
• The job in progress will be erased
• The machine will reboot automatically after approximately 30 seconds.
The operator can wait until the machine reboots automatically or touch “Reset” on the screen to reset the
machine immediately and go back to the copy screen.
If the operator does not touch “Reset”
The next message tells the operator that the machine will reset automatically and that the previous
job was lost and must be started again. After reading the message, the operator touches “Confirm”
on the screen. The next screen shows the number and title of the SC code, and stops until the
operator turns the machine off and on.
6. Troubleshooting
120
Summary of Contents for Aficio MP 171
Page 1: ...Model Gim P1a Machine Code M171 Field Service Manual September 2014 ...
Page 2: ......
Page 14: ...12 ...
Page 34: ...3 Preventive Maintenance 32 ...
Page 48: ...3 OPU Board x 7 4 Replacement and Adjustment 46 ...
Page 59: ...2 Hold the grip to pull the toner cartridge A out Toner Cartridge 57 ...
Page 105: ...2 Rear Cover Switch A x 1 Hook Electrical Components 103 ...
Page 106: ...4 Replacement and Adjustment 104 ...
Page 120: ...5 System Maintenance 118 ...
Page 166: ...MEMO 164 EN ...
Page 167: ...Model Gim P1a Machine Code M171 Appendices September 2014 ...
Page 168: ......
Page 186: ...2 Appendices Preventive Maintenance Tables 18 ...
Page 259: ...MEMO 91 ...
Page 260: ...MEMO 92 EN ...