3. Document Feeder Cover Open (Platen cover interlock switch open)
Symptom:
The problem cannot be solved with the procedures in the user’s manual.
Possible Causes:
•
The platen cover interlock switch is damaged.
•
The harness between the platen cover interlock switch and the SCU is
damaged.
•
The MBU is damaged.
Procedure:
Does 24 volts come to the platen cover interlock switch?
Yes
No
Is the harness damaged?
Yes
No
Replace the MBU.
Replace the harness.
Replace the platen cover interlock switch.
TROUBLESHOOTING
October 9th, 1995
TROUBLESHOOTING PROCEDURES
6-6