background image

Series

 SCK, 

Mechanical seal RG-4, stationary, double, liquid sealed

 

Page 

5

 

 
 

9220-014-en 

Revision  11 

TM 7827

 

Edition 03/2019 

 

Undo  back  plate  (for  instructions,  see 

Sections 

4.2.1

  and 

7.7.4

  in  the  installation  and  operating 

manual SCK). 

 

Move the back plate almost up to the impeller with 

light hammer blows. 

 

Bearing pedestal group 3:  

 

 

Labyrinth disc 

555 

must be secured with 

two  bolts 

prior 

to  the  dismantling  of  the 

impeller.  For  this  purpose  there  are  2 
bores  Ø5mm  in  the  bearing  pedestal. 
The double mechanical seal is relieved of 
pressure  as  a  result.  See  Dismantling  in 

Sections  7.7.1

  and 

7.7.5

  in  the  installa-

tion and operating manual SCK.  

 

 

Loosen  impeller 

230 

with  a  strap  wrench  or  as-

sembly  wrench. 

Right-hand  thread

.  Press  the 

housing cover towards the impeller. 

 

For assembly aid for impeller, see 

Section 10.1

 in 

the installation and operating manual SCK. 

 

Then completely remove the impeller 

230

. Remove 

the mating ring 

475/1

 and the flat gasket 

400/1

 

Remove  back  plate  (for  sequence,  see 

Sections 

4.2.1

  and 

7.7.4

  in  the  installation  and  operating 

manual  SCK)  with  centering  ring 

511

,  O-ring 

412/3

,  seal  face   

472/1

  and  intermediate  ring 

509/1

.   

 

Remove seal housing 

483

. Pull the rotary ring car-

rier 

485/1

  (comprising  thrust  ring 

474

,  spring 

477/1

, stud 

560/1 

and snap ring 

935/1

) out of the 

seal housing 

483

 
 

5.1.2  Dismantling the shaft sleeve  

 

Pull  the  shaft  sleeve 

524

  with  the  rotating  unit 

470/1 

which is still installed off the shaft. 

 

For  changing  the  rotating  unit,  undo  the  setscrew 

904/2

  (depending  on  the  design  of  the  shaft 

sleeve) and pull it off the shaft sleeve 

524

. Obser-

ve  the  operating  manual  of  the  mechanical  seal 
manufacturer. 

 

Remove mating ring 

475/2

 

If plastic bearing points of the mating ring 

475

 or of 

the  shaft  sleeve 

524 

are  destroyed,  they  can  be 

renewed by the pump manufacturer. 

 
 

5.2  Notes on assembly  

 

Only use original spare parts. 

 

Do not use any defective parts. 

 

It is essential to observe the installation and oper-

ating instructions of the pump, pressurisation sys-
tem and mechanical seal manufacturer. 

 

Bearing pedestal group 3:  

 

 

Always make sure that when installing 
the mechanical seal the labyrinth disc is 
secured by 2 bolts. 

 

The  bolts  must  be  removed  again  after  assembly 
of the impeller. 

 

The  rotary  ring  carrier 

485/1

  must  engage  in  the 

spring-type slotted pin 

531/1

.  Mark position befo-

rehand. 

 

The  seal  face 

472/1

  must  engage  in  the  studs 

560/1

. Mark position beforehand. 

 

In  the  case  of  the  shaft  sleeve  made  of  Al

2

O

3

  the 

rotating  unit 

470/1

  must  be  flush  with  the  key 

940/2

  and  tightened  with  the  setscrew 

904/2

.  In 

the  case  of  the  shaft  sleeve  made  of  stainless 
steel the key is positioned firmly against one end. 

 

When  pushing  on  the  mating  ring 

475/1,

  make 

sure that  the position of the flat section matches 
that on the shaft. 

 
 

 

Summary of Contents for RG-4

Page 1: ...ust be strictly observed before transport installation operation and maintenance Subject to change without notice Reproduction is generally permitted with indication of the source Richter Chemie Techn...

Page 2: ...es on assembly 5 6 Malfunctions 7 7 Sectional drawing 7 7 1 Legend 7 7 2 Stationary double mechanical seal RG 4 liquid sealed 8 Relevant documents Installation and operating manual SCK long life greas...

Page 3: ...are either plastic lined or made of other resistant materials e g silicon carbide 4 Commissioning Shutdown 4 1 Initial commissioning See installation and operating manual for the series SCK 4 2 Mecha...

Page 4: ...d electric sparks may result from these inadmissible modes of operation their occurrence can only be prevented by adhering to the intended use For examples see installation and operating manual SCK Se...

Page 5: ...of the seal housing 483 5 1 2 Dismantling the shaft sleeve Pull the shaft sleeve 524 with the rotating unit 470 1 which is still installed off the shaft For changing the rotating unit undo the setscre...

Page 6: ...chieved When supported by a circulation pump a smaller distance is possible The pipelines in the circuit of the supply system should be of stainless steel of the dimensions specified in the installati...

Page 7: ...1 Should there be any uncertainty about the remedy to be applied please inquire at the in house pump of fice or at the pump manufacturer s See also Section 8 in the installation and operating manual o...

Page 8: ...Series SCK Mechanical seal RG 4 stationary double liquid sealed Page 8 9220 014 en Revision 11 TM 7827 Edition 03 2019 7 2 Stationary double mechanical seal RG 4 liquid sealed...

Page 9: ...5241 2870 Email RichterShanghai Info idexcorp com Internet www richter ct com Richter Pumps Valves Inc 406 State Street Cedar Falls 50613 IA USA Tel 1 319 268 8038 Fax 1 319 273 8157 Email RichterCed...

Reviews: