background image

NOTICE: INSTALLER - Please provide this manual to the property owner 

responsible for the service and maintenance of the sump pump system.

INSTALLATION AND OPERATING INSTRUCTIONS

Specifications

Performance

Output Comparison

Model

Competitive 

Inverter

Richtech 

Inverter

Battery

12v 75AH

at full charge

12v 75AH

at full charge

Pump

Richtech 

1/2 HP Cast Iron

Richtech 

1/2 HP Cast Iron

Output Volume

792 Gal

3,505 Gal

Model #

INVRIC20

Input Voltage

DC 12V

Amp Rating

12.5A

Output Voltage

AC100V / 110V ±10%

Battery Charging Current

10A

Rated Power

1500W

Size

18.1” x 7.8” x 3.1”

Weight

13.4 lbs.

Color

Black

Warranty

3 Years

BACKUP POWER SYSTEM

PRIMARY SUMP PUMP

Summary of Contents for INVRIC20

Page 1: ...del Competitive Inverter Richtech Inverter Battery 12v 75AH at full charge 12v 75AH at full charge Pump Richtech 1 2 HP Cast Iron Richtech 1 2 HP Cast Iron Output Volume 792 Gal 3 505 Gal Model INVRIC20 Input Voltage DC 12V Amp Rating 12 5A Output Voltage AC100V 110V 10 Battery Charging Current 10A Rated Power 1500W Size 18 1 x 7 8 x 3 1 Weight 13 4 lbs Color Black Warranty 3 Years BACKUP POWER SY...

Page 2: ... be installed is 40 F to 120 F and well ventilated Avoid installing in direct sunlight DO NOT bypass grounding wires or remove the ground prong from the plug DO NOT use an extension cord NEVER plug this unit into an outlet while standing on a wet surface NEVER lift this product by the electrical power cord NEVER attempt to open or service this unit while it is connected to an electrical power supp...

Page 3: ...sition the Power Unit is also charging the deep cycle battery The Charging Indicator will be RED while charging the battery and GREEN once the battery is fully charged When you loose household power the Power Unit will automatically activate and convert your 12VDC Battery to 120 VAC Pure Sine Wave output at both of the Power Unit Outlets It is recommended that you keep both the Charger Switch and ...

Page 4: ...e Power Switch The LEDs above both switches should be green Your system is now properly setup TROUBLESHOOTING WARNING Always disconnect the power unit from power sources before handling This guide is designed to help identify reasons for potential operating problems It is not a service guide Dismantling of the power unit voids warranty Servicing of power unit should be referred to the factory or i...

Page 5: ...cked check valve PUMP CYCLES TOO OFTEN OR RUNS CONSTANTLY 1 Check Valve may have failed causing discharged water to return to the sump pit Cycle pump and look for water rushing back through the pump inlet Replace Check Valve as necessary 2 Pump May be sized incorrectly Check with your local plumber for recommendation 3 Pump Inlet may be blocked Unplug pump from power source and clean inlet SYSTEM ...

Page 6: ...lity of the customer This warranty is not transferable and may not be assigned This Warranty shall be governed and construed under laws of the sate of Ohio The Warranty Period will not be extended by any replacement or repair performed under this Warranty THIS WARRANTY IS THE EXCLUSIVE WARRANTY AND REMEDY PROVIDED BY RICHTECH ALL OTHER WARRANTIES EXPRESSEDORIMPLIED INCLUDINGWARRANTIESORMERCHANTABI...

Page 7: ... 2021 RICHTECH INDUSTRIES 1 800 677 7791 RICHTECHINDUSTRIES COM 7 FOR YOUR RECORDS Date of Purchase Place of Purchase Serial Number Installed by Model Number ...

Page 8: ... 2021 RICHTECH INDUSTRIES 1 800 677 7791 RICHTECHINDUSTRIES COM 8 ...