background image

23

English

 

WARNING: 

Risk of electric shock

. Before any troubleshooting, switch off the engine. Suspected 

malfunctions are often due to causes that users can fix themselves. Therefore check the product using this section. In 
most cases the problem can be solved quickly.

Proble

m

s  

Probable Causes

Solutions

Engine does not 
start

The fuel tank is empty.

Refuel the fuel tank with proper fuel.

The engine switch was set to OFF. 

Set the engine switch to the «RUN» position.

The oil was not enough.

Refill the oil to the recommended level.

Spark plug is defective.

Clean the electrode or change with a new one.

The engine is flooded.

Set the engine switch to the «RUN» position, remove 
the spark plug and wipe up the fuel, then pull out 
the starter rope 5-10 times to drain out the fuel in 
cylinder. Reinstall the spark plug.

The fuel tube is broken.

Contact with the local service for repair.

Engine lack of 
power

Air filter is dirty .

Clean the air filter.

Spark plug is dirty .

Clean it.

Fuel filter was blocked. 

Contact with the local service for repair.

Valve tolerance is set incorrect.

Contact with the local service for help. 

AC socket does 
not work

Overload warning.

Disconnect the appliances, and then press the output 
reset button.

Circuit protector engaged.

Disconnect the appliances, press the AC breaker.

DC (USB) socket 

does not work

Overload warning.

Disconnect all the appliances, and then press the 
output reset button.

Circuit protector engaged.

Disconnect the appliances, press the DC breaker.

Generator makes 

BwLOPDLwOPJTF

If the knocking or pinging occurs 
under normal load, the problem may 
be with the  wrong gasoline being 
used.

Switch to a different brand of gasoline, making sure 
that the octane rating is 86 or higher. If problem 
continues, contact your nearest authorised service 
centre.

TROUBLESHOOTING

Summary of Contents for Power Smith PGA2200i

Page 1: ...or Operator s Manual SAVE THIS MANUAL FOR FUTURE REFERENCE WARNING To reduce the risk of injury user must read and understand this operator s manual before operating this product 888 552 8665 TOLL FRE...

Page 2: ...ABLE OF CONTENT CALIFORNIA PROPOSITION 65 WARNING The engine exhaust from this product contains chemicals known to the state of California to cause cancer birth defects or other reproductive harm Cert...

Page 3: ...hould be consid ered a permanent part of the generator and should remain with it if it is resold t Keep children and pets at least 10 feet away from the generator when it is in operation t Fuel is com...

Page 4: ...ed area with the fuel tank empty Fuel should not be stored near the generator t Before use the generating set and its electrical equipment including lines and plug connections should be checked to ens...

Page 5: ...zard Fuel and its vapors are extremely ammable Do not add fuel while the product is operating Hot Surface Exhaust Gases To reduce the risk of injury or damage avoid contact with any hot surface and do...

Page 6: ...njury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION Without Safety Alert Symbol Indicates important information not related to...

Page 7: ...h running speed turn off the appliance or tool immediately to avoid equipment damage Always check the requirements of the tool or appliance being used compared to the rated output of the generator NOT...

Page 8: ...Plug in the turn on the rst load preferably the largest load you have 3 Allow time to let the generator to run smoothly and the attached to operate properly 4 Connect and turn on the second load 5 Ag...

Page 9: ...acement 79 8 cc Rated Speed 5000 RPM No Load Speed 3000 RPM Spark Plug TORCH E6TC Oil Tank Volume 400 CM3 Fuel Unleaded Gasoline Lubricate Oil SAE 10W30 above API SJ grade UNPACKING CONTENTS IMPORTANT...

Page 10: ...gine Revolution Speed 13 Running Cumulative Hours 14 Ground Terminal 15 Digital Display Screen 16 Parallel Connectors 17 Display Locking Button 18 USB Ports 19 Running Hours Reset Button 20 Wattage In...

Page 11: ...dle 30 Handle Locking Pin 31 Unfold Locking Pin 32 Transportation Handle 33 Spark Arrester 34 Transportation Wheel 35 Maintenance Cover 36 Muf er Shield 37 Spark Plug 38 Carburetor Drain Screw 39 Air...

Page 12: ...arter is used along with the Engine Switch to start the generator s engine RESET BUTTON The reset button is used to restore power if an overload occurs To restore power remove all loads and depress th...

Page 13: ...plugged into the control panel outlets CAUTION Starting the generator with loads already applied to it could result in damage to any appliance being powered off the generator during the brief start up...

Page 14: ...etting the dirty and water in the fuel tank DANGER Risk of re and serious burns Never remove fuel cap when unit is running Shut off engine and allow the unit to cool at least ve minutes Remove cap slo...

Page 15: ...ease according to the electric load it can help to decrease the fuel consumption If the auto idle switch is set in the OFF position the engine will run at high speed all the time Do not allow the reco...

Page 16: ...reen and the overload indicator lights red instead press the reset button 3 Con rm that the appliances to be used are switched off and insert the plug of the AC appliances into the AC sockets The DC s...

Page 17: ...DC receptacle of the generator 5 Connect the vehicle ground cable to the negative battery terminal OUTPUT AND OVERLOAD INDICATORS The Output Indicator will light green during normal operating conditi...

Page 18: ...NING Avoid skin contact with engine oil or gasoline Prolonged skin contact with engine oil or gaso line can be harmful Frequent and prolonged contact with engine oil may cause skin cancer Take protect...

Page 19: ...to a recycling center Do not discard it in a trash bin dump it on the ground or pour it down a drain CHECKING CLEANING AIR FILTER FIG 15 A dirty air lter will restrict air ow to the carburetor To prev...

Page 20: ...re 1 8 to 1 4 turn after being seated 9 Reinstall the spark plug cap on the spark plug securely 10 Reinstall the maintenance cover CAUTION A loosen spark plug can overheat and damage the engine Overhe...

Page 21: ...ight when putting the generator on a vehicle If the generator is left in an enclosed vehicle for many hours high temperature inside the vehicle could cause fuel to vaporize resulting in a possible exp...

Page 22: ...nd pour about a tablespoon of clean engine oil into the cylinder Crank the engine several revolutions to distribute the oil and then reinstall the spark plug t Reinstall the spark plug cap on the spar...

Page 23: ...spark plug The fuel tube is broken Contact with the local service for repair Engine lack of power Air lter is dirty Clean the air lter Spark plug is dirty Clean it Fuel lter was blocked Contact with t...

Page 24: ...red by this warranty and it is not transferable Prior to returning your tool to store location of purchase please call Toll Free Help Line for possible solutions THIS PRODUCT IS NOT WARRANTED IF USED...

Page 25: ...73 NOTES...

Page 26: ...74 NOTES...

Page 27: ...75 NOTES...

Page 28: ...Richpower Industries Inc 736 Hampton Road Williamston SC USA www richpowerinc com 2018 08 V01...

Reviews: