background image

FIG 11

16

English

OPERATION

Turn the auto idle switch to the OFF position and connect the appliance to the generator. If the engine still will not reach 
normal operating speed, check that the appliance does not exceed the rated load capacity of the generator.

USING THE GENERATOR

Before using the generator, be aware of the generator's capacity:

2200W: For short time (3 seconds) surge, do not exceed this rated surge power.
2000W: Maximum power for 

limit operation up to 30 minutes.

1700W: 

For continuous operation, do not exceed this rated running power.

In any case, the total wattage of all appliances connected must be considered. Most appliance motors require more than 
their rated wattage for startup. Refer to 

«GENERATOR CAPACITY»

t

Do not exceed the current limit specified for the power outlets.

t

Do not connect the generator to an automatic transfer switch. Severe damage to the generator and engine will result.

t

Do not modify or use the generator for other purposes than it is intended for. 

t

Do not connect an extension to the exhaust pipe.

t

When an extension cable is required, be sure to use a tough rubber sheathed flexible cable.

t

Keep all cooling holes open and clear of debris, mud, water, etc. Cooling holes and air intake are located on the bottom 
cover. If the cooling holes and air intake are blocked, the generator may overheat, lack of output power and damage 
the engine, inverter, or windings.

t

The DC socket can be used while the AC power is in use. If you use both at the same time, be sure not to exceed the 
total power for AC and DC.

1. 

Connect the ground terminal.

2. 

Start the engine according to «STARTING THE ENGINE». If the output 
indicator doesn't light green and the overload indicator lights red 
instead, press the reset button.

3. 

Confirm that the 

appliances

 to be used are switched off, and insert 

the plug of the AC 

appliances

 into the AC sockets.

The DC socket should only be used for charging 12 volt automotive-
type batteries, the zero load voltage is 14.2V.
The USB socket should only be used for charging 5 volt mobile or 
digital equippment, e.g. mobile power bank.

4. 

Switch on the 

appliances

 to be used. Start with the 

appliance

 with the 

highest surge/starting power. 

In case of overload or when trouble occurs for the 

appliances

 being used, the output indicator light (green) will go out, 

the overload indicator will turn red and no electrical power output. 

 

Using DC Socket

The DC socket should only be used for charging 12 volt automotive-type batteries, the zero load voltage is 14.2V.

1. 

Connect the charging cables to the DC outlet of the generator.

2. 

Connect the red lead of battery charging cable to the positive (+) battery terminal and the black lead to the negative 
(-) battery terminal.

To prevent the possibility of creating a spark near the battery, connect charging cable first to the generator, then to the
battery. Disconnect cable first at the battery. Reconnect the vehicle’s grounded battery cable after the charging cables 
are removed. This procedure will prevent the possibility of a short circuit and sparks if you make accidental contact 
between a battery terminal and the vehicle’s frame or body.

Do not attempt to start an automobile engine with the generator still connected to the battery. The generator may be 
damaged. Connect the positive battery terminal to the positive charging cord. Do not reverse the charging cables, or 
serious damage to the generator and/or battery may occur.

 

WARNING: 

The battery gives off explosive gases; Keep sparks flames and cigarettes away. Provide 

adequate ventilation when charging.

Summary of Contents for Power Smith PGA2200i

Page 1: ...or Operator s Manual SAVE THIS MANUAL FOR FUTURE REFERENCE WARNING To reduce the risk of injury user must read and understand this operator s manual before operating this product 888 552 8665 TOLL FRE...

Page 2: ...ABLE OF CONTENT CALIFORNIA PROPOSITION 65 WARNING The engine exhaust from this product contains chemicals known to the state of California to cause cancer birth defects or other reproductive harm Cert...

Page 3: ...hould be consid ered a permanent part of the generator and should remain with it if it is resold t Keep children and pets at least 10 feet away from the generator when it is in operation t Fuel is com...

Page 4: ...ed area with the fuel tank empty Fuel should not be stored near the generator t Before use the generating set and its electrical equipment including lines and plug connections should be checked to ens...

Page 5: ...zard Fuel and its vapors are extremely ammable Do not add fuel while the product is operating Hot Surface Exhaust Gases To reduce the risk of injury or damage avoid contact with any hot surface and do...

Page 6: ...njury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION Without Safety Alert Symbol Indicates important information not related to...

Page 7: ...h running speed turn off the appliance or tool immediately to avoid equipment damage Always check the requirements of the tool or appliance being used compared to the rated output of the generator NOT...

Page 8: ...Plug in the turn on the rst load preferably the largest load you have 3 Allow time to let the generator to run smoothly and the attached to operate properly 4 Connect and turn on the second load 5 Ag...

Page 9: ...acement 79 8 cc Rated Speed 5000 RPM No Load Speed 3000 RPM Spark Plug TORCH E6TC Oil Tank Volume 400 CM3 Fuel Unleaded Gasoline Lubricate Oil SAE 10W30 above API SJ grade UNPACKING CONTENTS IMPORTANT...

Page 10: ...gine Revolution Speed 13 Running Cumulative Hours 14 Ground Terminal 15 Digital Display Screen 16 Parallel Connectors 17 Display Locking Button 18 USB Ports 19 Running Hours Reset Button 20 Wattage In...

Page 11: ...dle 30 Handle Locking Pin 31 Unfold Locking Pin 32 Transportation Handle 33 Spark Arrester 34 Transportation Wheel 35 Maintenance Cover 36 Muf er Shield 37 Spark Plug 38 Carburetor Drain Screw 39 Air...

Page 12: ...arter is used along with the Engine Switch to start the generator s engine RESET BUTTON The reset button is used to restore power if an overload occurs To restore power remove all loads and depress th...

Page 13: ...plugged into the control panel outlets CAUTION Starting the generator with loads already applied to it could result in damage to any appliance being powered off the generator during the brief start up...

Page 14: ...etting the dirty and water in the fuel tank DANGER Risk of re and serious burns Never remove fuel cap when unit is running Shut off engine and allow the unit to cool at least ve minutes Remove cap slo...

Page 15: ...ease according to the electric load it can help to decrease the fuel consumption If the auto idle switch is set in the OFF position the engine will run at high speed all the time Do not allow the reco...

Page 16: ...reen and the overload indicator lights red instead press the reset button 3 Con rm that the appliances to be used are switched off and insert the plug of the AC appliances into the AC sockets The DC s...

Page 17: ...DC receptacle of the generator 5 Connect the vehicle ground cable to the negative battery terminal OUTPUT AND OVERLOAD INDICATORS The Output Indicator will light green during normal operating conditi...

Page 18: ...NING Avoid skin contact with engine oil or gasoline Prolonged skin contact with engine oil or gaso line can be harmful Frequent and prolonged contact with engine oil may cause skin cancer Take protect...

Page 19: ...to a recycling center Do not discard it in a trash bin dump it on the ground or pour it down a drain CHECKING CLEANING AIR FILTER FIG 15 A dirty air lter will restrict air ow to the carburetor To prev...

Page 20: ...re 1 8 to 1 4 turn after being seated 9 Reinstall the spark plug cap on the spark plug securely 10 Reinstall the maintenance cover CAUTION A loosen spark plug can overheat and damage the engine Overhe...

Page 21: ...ight when putting the generator on a vehicle If the generator is left in an enclosed vehicle for many hours high temperature inside the vehicle could cause fuel to vaporize resulting in a possible exp...

Page 22: ...nd pour about a tablespoon of clean engine oil into the cylinder Crank the engine several revolutions to distribute the oil and then reinstall the spark plug t Reinstall the spark plug cap on the spar...

Page 23: ...spark plug The fuel tube is broken Contact with the local service for repair Engine lack of power Air lter is dirty Clean the air lter Spark plug is dirty Clean it Fuel lter was blocked Contact with t...

Page 24: ...red by this warranty and it is not transferable Prior to returning your tool to store location of purchase please call Toll Free Help Line for possible solutions THIS PRODUCT IS NOT WARRANTED IF USED...

Page 25: ...73 NOTES...

Page 26: ...74 NOTES...

Page 27: ...75 NOTES...

Page 28: ...Richpower Industries Inc 736 Hampton Road Williamston SC USA www richpowerinc com 2018 08 V01...

Reviews: