Installation for Single Swing Gate

Step 1:

 

Disengage the clutch of the swing arm with the Manual Release Key. Make sure you can move the gate 

by hand, so the gate can swing freely during installation of the Electric Lock.

Step 2:

 

With the gate in the closed position, determine the best location for the lock and receiver. The lock and 

receiver must be level and aligned with the opener. The lock and receiver should have a solid surface or 

tube fence to provide stability

Step 3:

 

For a 

Metallic Tube gate,

 if the thickness of the fence post is bigger than or equal to 3mm, you can 

thread on the fence post, and fasten the lock and receiver only using bolts (without nuts). Otherwise, drill 

holes throughout the fence post and fasten the lock and receiver with bolts, lock washers and nuts. Of 

course you could also weld them directly.

For a 

Chain Link gate,

 you will need U Bolts, saddles, lock washers and nuts for the lock and receiver.

Step 4:

 

Recheck the locks position and alignment, make sure the electric lock is working correctly.

Step 5:

 

Connect the power cables for the lock to the control board of swing gate opener and Lock plus board. 

(See Figure E and F).

Note: Be sure that the clutch of the swing arm is engaged before you prepare to activate your 

opener (Use the Manual Release Key)

Summary of Contents for GTR169

Page 1: ...work correctly the gate must close firmly engaging the lock catch against the lock receiver 3 The Electric Lock must be installed on the outside of the gate if the gate is Push to Open 4 Due to the various mounting conditions mounting hardware is not provided Read this manual carefully to determine the mounting hardware required for your condition 5 For dual gate the lock must be installed on the ...

Page 2: ...of the fence post is bigger than or equal to 3mm you can thread on the fence post and fasten the lock and receiver only using bolts without nuts Otherwise drill holes throughout the fence post and fasten the lock and receiver with bolts lock washers and nuts Of course you could also weld them directly For a Chain Link gate you will need U Bolts saddles lock washers and nuts for the lock and receiv...

Page 3: ...he fence post is bigger than or equal to 3mm you can thread on the fence post and fasten the lock and receiver only using bolts without nuts Otherwise drill holes throughout the fence post and fasten the lock and receiver with bolts lock washers and nuts Of course you could also weld them directly For a Chain Link Gates you will need U Bolts saddles lock washers and nuts for the lock and receiver ...

Page 4: ...GTR169 Electric Lock Manual Rev 1 4 ...

Page 5: ...has been connected with the E Plus board Disconnect the terminals so that the electric lock wires can be fed through the access port and reconnected to the E Plus board The other wires of the electric lock should be connected to the control board using the following wiring diagram or the wiring diagram in the swing arm manual ...