INSTRUCTIONS FOR INSTALLATION AND USE

05-16

39417

FIREBOX - INSERT

1000 HORIZON FV

1. TECHNICAL CHARACTERISTICS 

3

2. CONNECTION POSSIBILITIES

4

3. INSERT INSTALLATION

5

4. FIREBOX INSTALLATION

7

5. USE 

10

6. MAINTENANCE  

12

7. WARRANTY

12

Illustrations no-contractual.

Summary of Contents for 1000 Horizon FV

Page 1: ...TION AND USE 05 16 39417 FIREBOX INSERT 1000 HORIZON FV 1 TECHNICAL CHARACTERISTICS 3 2 CONNECTION POSSIBILITIES 4 3 INSERT INSTALLATION 5 4 FIREBOX INSTALLATION 7 5 USE 10 6 MAINTENANCE 12 7 WARRANTY...

Page 2: ...safe place The manufacturer s liability is limited to the supply of the appliance It may not be held liable in the event of any failure to respect these instructions The following are especially prohi...

Page 3: ...distributor outlet diameter 150 mm External air inlet diameter 75 mm Minimal dimensions of chimney block 20 x20 cm Min of tubing or insulated metal box 150 mm Min height above firebox 4 m DRAUGHT 10 P...

Page 4: ...DTU 24 1 Warm air is blown in front of the appliance Warm air distribution is possible with nozzles 125 or 150 option In this case the warm air blows out only over the firebox Fig 2 2 Combustion air...

Page 5: ...ing is optimal with an approximately 40 m3 hour of fresh air consumption A system of ventilation french VMC a centralized ventilation system a n extractor hood can perturb the functioning of the fireb...

Page 6: ...5 Lock the baffle in the firebox on the brackets 3 7 CONNECTION TO THE SMOKE FLUE Remove the smoke baffle 3 6 Connect the nozzle to the flue 3 3 from inside the firebox Lock the baffle into the firebo...

Page 7: ...mbustion air supply connected outside A direct supply of air combustion in the room is possible respect the following recommendations 4 1 6 1 Combustion air not connected If no outside nozzle connecti...

Page 8: ...s 4 6 1 2 3 5 6 7 8 9 10 FOYER 4 13 14 11 12 15 16 17 18 19 FIREBOX MONTAGE 1 Supporting wall class M0 materials 2 Decorative hood material according to model 3 Air access 4 Air access through firepla...

Page 9: ...ahead of the firebox to the room fig 4 6 Rep 17 4 7 WARM AIR DISTRIBUTION Connect the warm air nozzless option available sp cific documentation Switch the warm air direction valve to direct warm air...

Page 10: ...openings communicating with the outside of the hood be airtight as regards the lower part of the hood in order to avoid warm air escaping upwards Insulate the side resting against the wall the pipe a...

Page 11: ...onal Start with a small fire then in stages increase the load The progressive rise in the temperature allows the materials to dilate slowly and stabilise Smoke and a smell will be given off at first d...

Page 12: ...l operation When operating at reduced speed the clean glass system is less efficient 6 4 OBLIGATORY CHIMNEY SWEEPING The law in France requires that the chimney be swept twice a year including once du...