![Rice Lake Summit SD-1150-WP Operation Manual Download Page 19](http://html1.mh-extra.com/html/rice-lake/summit-sd-1150-wp/summit-sd-1150-wp_operation-manual_1454241019.webp)
Specifications
© Rice Lake Weighing Systems
●
All Rights Reserved
15
6.0
Specifications
Electrical Grounding
For systems where the scale is connected to a 115 VAC circuit, the indicator must be directly connected to an earth ground with a ground interface cable of
no more than 3 W resistance throughout its length.
Power
120 VAC-9 VDC-50 Hz / 230 VAC-9 VDC-50 Hz
Battery Type
AA Alkaline
Battery Use
25 hours of continuous use
Automatic power-off can be configured
Environmental
Operating Temperature
50°F to 104°F (14°C to 40°C)
Storage Temperature
32°F to 158°F (0°C to 70°C)
Humidity
85% relative humidity
Dimensions
(H x L) 36 in x 30 in
Handrail and mounting hardware
(W x L) 36 in x 36 in
Mild steel painted pit frame
Safe Static Overloading Capacity
Maximum
150% of scale capacity
Load Cell Excitation
Rated Excitation
10 VDC
Maximum Excitation
15 VDC
Grade Level Requirements
The supporting surface for the four feet of the scale must be level within 1/4'' of horizontal.
Certifications and Approvals
E113896