Summit 3000 Low-Profile Floor Scale
4
Visit our website
2.3 Adjust feet
The scale feet are secured with a jam nut (located next to each load cell) during shipping to protect the load cells.
1. Loosen the jam nut.
2. Screw one foot into each load cell and turn until each foot touches either the load cell or the underside of the deck.
3. Unscrew each foot three complete turns.
4. Place a spirit level on the deck.
5. Adjust any high corners until they just contact the floor surface.
6. Recheck the deck with the spirit level, when all feet contact the floor, to ensure it is within 1/4'' of level.
Figure 2-2. Jam Nut Location on Scale Foot
2.4 Anchor Plate Installation
Optional floor anchor plates (PN 75819) are available for permanent applications and should be secured to the floor to prevent
sideways movement of the scale.
1. Using proper lifting technique (
), lift the scale so the feet are approximately one inch off the floor.
2. Slide mounting plates under two feet, diagonal from each other.
3. Lower the scale back to the floor and position the plates so that the boltdown holes are accessible.
4. Using the mounting plates as templates to drill pilot holes into the floor for suitable anchor bolts.
5. Bolt the plates to the floor using 1/2'' anchor bolts.
6. Recheck foot adjustment and deck level.
For installations using access ramps, mounting plates are not necessary, the ramps have built-in mounting plates.
Figure 2-3. Mounting Plate Installation
Jam nut needs to be loosened
prior to adjusting scale feet.
Scale is Shown Upside
Down for illustration
purposes.
Note
Note
3.50"
3.50"
.56” diameter
Anchor Plate