SCT-2200 Wi-Fi Module Parameters
© Rice Lake Weighing Systems
●
All Rights Reserved
17
4.3.1 TCP Server
In this mode, the module is listening on the specified port, waiting for the TCP Client connection. If connected, all TCP data is
sent directly to the serial port endpoint and the data of the serial endpoint is sent to the TCP Client.
Figure 4-14. TCP Server Model
4.3.2 TCP Client
In this mode, the module is connected to the specified domain/IP port. All the data sent from the TCP Server-side endpoints will
be sent directly to the serial port, the data from the serial endpoints sent to the TCP Server-side. Abnormal network disconnect
will cause the module active reconnect. TCP Active reconnection function enable, TCP Server initiative disconnected, the
module will immediately take the initiative to reconnect, and otherwise the module will not reconnect.
Figure 4-15. TCP Client Model
4.3.3 UDP Server
In this mode, the module opens the local designated port. The module will send the data to the serial port, and record the
remote ip, port. The module will record only the last information on the remote connection. Serial received data will be sent
directly to the recorded remote ip, port.
Figure 4-16. UDP Server Model
SCT-2200 Wi-Fi
TCP Client
TCP Server
TCP Client
TCP Client
SCT-2200 Wi-Fi
TCP Client
TCP Server
SCT-2200 Wi-Fi
UDP Server
UDP Client