21
1.2.5
Program Menu
Figure 1-9. Program Menu
XXXXXXX
XXXXXXX
PWRUPM
GO
OIML
REGULA
000000
number
CONSNU
DELAY
SETPNT
PROGRM PFORMT
SERIAL
CALIBR
CONFIG FORMAT
000000
number
CONSTU
NTEP
CANADA
1
UID
VERS
DIGIN ALGOUT
DA TFMT
MMDDYY
DA TE
DDMMYY
YYMMDD
YYDDMM
DA TSEP
SLASH
DASH
SEMI
TIMFMT
12HOUR
TIME
24HOUR
TIMSEP
COLON
COMA
NONE
PROGRM Menu
Parameter
Choices
Description
Level 2 submenus
PWRUPM
GO
DELAY
Power up mode. In GO mode, the indicator goes into operation immediately after a brief power
up display test.
In DELAY mode, the indicator performs a power up display test, then enters a 30-second
warm up period. If no motion is detected during the warm up period, the indicator becomes
operational when the warm up period ends; if motion is detected, the delay timer is reset and
the warm up period repeated.
REGULA
NTEP
OIML
CANADA
NONE
Regulatory mode. Specifies the regulatory agency having jurisdiction over the scale site.
OIML, NTEP, and CANADA modes allow a tare to be acquired at any weight greater than zero.
NONE allows tares to be acquired at any weight value.
OIML, NTEP, and CANADA modes allow a tare to be cleared only if the gross weight is at no
load. NONE allows tares to be cleared at any weight value.
NTEP and OIML modes allow a new tare to be acquired even if a tare is already present. In
CANADA mode, the previous tare must be cleared before a new tare can be acquired.
NONE, NTEP and CANADA modes allow the scale to be zeroed in either gross or net mode as
long as the current weight is within the specified ZRANGE. In OIML mode, the scale must be in
gross mode before it can be zeroed; pressing the ZERO key in net mode clears the tare.
UID
1
Specifies the unit identification number. Value specified can be any numeric value, up to six
digits.
DATE
DATFMT
DATSEP
Allows selection of date format and date separator. See Level three parameter for descriptions.
TIME
TIMFMT
TIMSEP
Allows selection of time format and separator. See level three parameter for descriptions.
CONSNU
000000
number
Consecutive numbering. Allows sequential numbering for print operations. The consecutive
number value is incremented following each print operation.
The initial value of this parameter is set to the start up value specified on the CONSTU
parameter. Changing either CONSTU or CONSNU immediately resets the consecutive number
used for printing.
CONSTU
000000
number
Consecutive number start up value. Specifies the initial consecutive number (CONSNU) value
used when the indicator is powered on.
Level 3 submenus
Table 1-6. Program Menu Parameters