Summary of Contents for DIGI DS-520

Page 1: ...O O O Op p p pe e e er r r ra a a at t t tii i io o o on n n nM M M Ma a a an n n nu u u ua a a all l l D D D Dii i ig g g gii i it t t ta a a all l l II I In n n nd d d dii i ic c c ca a a at t t to...

Page 2: ...0 INSTALLATION 5 6 3 1 Un packing 5 3 2 Inspection 5 3 3 Re packing 5 3 4 Un locking Procedure 5 6 4 0 DS 520 OPERATIONAL PROCEDURES 7 8 4 1 Power On Off 7 4 2 Automatic Shut Off 7 4 3 Re zero 8 4 4 T...

Page 3: ...ntinuous use Fast self test procedure when power on Selectable automatic shut off time which prolongs battery life Two point low battery detect A When battery is weak the battery indicator will light...

Page 4: ...ght display to zero TARE Key Set or clear a tare ON OFF Key Turn the power ON or OFF 1 4 Indicators Lamps Zero On when zero point is adjusted and when weight is stable Net On when tare reduction is pe...

Page 5: ...humidity 15 85 RH Power consumption 0 07w when 6V 0 1w when 9V 2 1 3 Analog specification Input sensitivity 0 67mV V 10kg 20kg all other capacities 1mV V Zero adjust range 40 Full Scale Zero balance...

Page 6: ...ection of the scale should be performed If any damage has been incurred during transportation notify the shipper and Rice Lake Weighing systems immediately Instructions for assessment of damage and fu...

Page 7: ...6 Unlocking Procedure Continued...

Page 8: ...lay will then briefly show all segments then blank for a second then go into weighing mode 1 Begin with the scale turned off 2 Press and hold the ON OFF key for 6 seconds This sets the Timer for 10 mi...

Page 9: ...howing 0 00 Example based on 60 lb scale 1 Place 25 lb on the scale 2 Press the REZERO key The display will show all segments briefly then go to 25 00 25lb exceeds the 40 limit of the rezero range 4 4...

Page 10: ...0 0 1 1 5 Press the TARE key To store spec data and advance to the next spec S1 0 0 0 6 Press the REZERO key To save specs to memory and return to the weighing mode 5 2 Specification Entry and Span Ad...

Page 11: ...en span is calibrated the scale will return to the weighing mode 60 00 NOTE To exit maintenance mode Press the REZERO key at any step except when are displayed 5 3 Internal Count Display Example Begin...

Page 12: ...Used S5 Not Used S6 Auto Tare Clear V 1 21 0 yes 1 no 5 5 Error Message List The following message will appear when an invalid operation is performed Message Remark Appropriate Operation OF When displ...

Page 13: ...nternal maintenance is not normally required and if it is should not be attempted except by a qualified authorized service technician 5 6 2 Calibration The following procedure should be followed perio...

Page 14: ...ccident misuse neglect alteration improper installation improper repair or improper testing RLWS shall be the sole judge of all alleged non conformities Such equipment has not been modified altered or...

Reviews: