Altralite Portable Low-Profile Floor Scale
12
Visit our website
4.3.1 Load Cell Wiring to Junction Box
The four load cells are each wired to their respective terminals in the junction box according to the corner numbering system
, and the coloring code in Table 4-2.
Pull excess cable out of the junction box enclosure and tighten the cord grip dome nuts with a wrench. To be watertight, the nuts
must be tightened to the point where the rubber sleeving begins to protrude out of the nut. Finally, pull on each of the four
cables to make sure that they do not slip.
Figure 4-4. Corner Numbering - Top View
Installations may vary. Check the load cell color code of the unit.
Wire Code
Signal
Red
+ Excitation
Black
- Excitation
Green
+ Signal
White
- Signal
Bare or Clear
Shield
Table 4-2. Load Cell Wiring
1
4
2
3
Note