VI. MAINTENANCE AND STORAGE

 

 

 

Before any intervention on product, ensure that product is disconnected form its 
power source. 

 
6.1- Maintenance 

- In winter the pump must be thoroughly drained or kept in "frost free" conditions.  
- Regularly rinse out the pump with clean water, including the suction circuit.  
- After using the pump in a swimming pool or garden pond/basin, thoroughly rinse it with clean 
water, including the suction line. 
- Avoid pumping liquid containing abrasive materials such as sand.  
- Before each re-use, ensure that all parts of the pump are in good working order. 
- Clean plastic parts with a soft clean cloth. 
- Do not use aggressive cleansers (solvents or abrasive cleansers), or an abrasive sponge. 
 

6.2- Breakdown 

Never attempt to dismantle the pump.  
If necessary, have it checked and repaired by an authorized centre (consult your dealer). 
 

6.3- Storage 

Clean the pump. 
Pump must be stored in a dry, ventilated location. Always lock up product and keep out of reach of 
children. 
 

6.4- Disposal 

- Do not dispose the product with household garbage. Do not throw into the environment. 
- Dispose of the product in a collection centre for waste of electrical and electronic equipment, or a 
waste drop-off centre; or seek advice from your local municipality. 
- Disposal of the product, accessories and packaging should be carried out according to local 
regulations governing environment protection.  
 

Summary of Contents for 516426

Page 1: ...Manuale di istruzioni e di manutenzione R f Art Nr PRPVC801MC3 516426 Imp par by Ribimex S A 56 Route de Paris FR 77340 Pontault Combault Imp da Ribimex Italia s r l Via Igna 18 IT 36010 Carr Vi v_20...

Page 2: ...e injury and or damages Please keep this manual for future reference AVVERTENZA Leggere attentamente questo manuale di istruzioni prima di utilizzare l attrezzo Il funzionamento non corretto pu causar...

Page 3: ...e ou au centre de recyclage le plus proche Demander conseil aux autorit s locales ou votre d chetterie locale 3 1 LIRE TOUTES LES INSTRUCTIONS AVANT D UTILISER CE PRODUIT 1 Garder l aire de travail pr...

Page 4: ...plus s re performance 13 D connecter le produit Quand il n est pas utilis avant un entretien et pour changer les accessoires 14 Eviter les d marrages intempestifs S assurer que l interrupteur est en...

Page 5: ...3 3 Recommandations et instructions de s curit 1 La tension d alimentation doit correspondre celle indiqu e sur l tiquette des caract ristiques 230V 50Hz N utiliser aucun autre type d alimentation 2 L...

Page 6: ...teur peut se mouvoir librement pr voir environ 50cm autour de la pompe 3 Les trous d aspirations ne devront jamais tre obstru s Il est donc pr f rable que la pompe ne soit pas pos e directement sur le...

Page 7: ...est redevenue normale le moteur red marre Ne pas approcher les doigts de la turbine pendant cette phase Si une intervention est n cessaire d brancher la fiche de prise de courant au pr alable 3 La pom...

Page 8: ...t e des enfants soit en hauteur soit sous clef 6 4 Mise au rebut En fin de vie ne pas jeter le produit avec les ordures m nag res ou dans l environnement Apporter le produit une d chetterie ou un cent...

Page 9: ...er information for its safe disposal 3 1 READ ALL THE INFORMATION BEFORE OPERATING THE PRODUCT 1 Keep work area clean Cluttered areas and benches invite accidents and injuries 2 Consider work area env...

Page 10: ...ch what you are doing Use common sense Do not operate product when you are tired under the influence of alcohol prescription medicines or drugs 17 Check damaged parts Before further use or reuse of th...

Page 11: ...V 50Hz Do not use any other type of power supply 2 The pump should be supplied by a circuit containing a residual current circuit breaker RCCD with a sensitivity not exceeding 30 mA Consult a qualifi...

Page 12: ...e to modify the water heights that trigger starting and stopping of the pump 3 To adjust the cut in cut out height fix the float switch cable to the float switch lock 5 provided for this purpose locat...

Page 13: ...ot designed for continuous operation e g continuous water circulating operation The submersible pump must be immersed before switching on Place pump into water then let it purge the air air bubbles th...

Page 14: ...parts with a soft clean cloth Do not use aggressive cleansers solvents or abrasive cleansers or an abrasive sponge 6 2 Breakdown Never attempt to dismantle the pump If necessary have it checked and r...

Page 15: ...gio Contattare l ente locale preposto o l azienda incaricata per ulteriori informazioni sul metodo sicuro di smaltimento 3 1 LEGGERE TUTTE LE INFORMAZIONI PRIMA DI UTILIZZARE IL PRODOTTO 1 Mantenere i...

Page 16: ...l attrezzo utilizzato con un estensione utilizzare soltanto estensioni concepite e previste per sopportare la corrente che alimenta l attrezzo 16 Fare sempre attenzione Guardare quello che si fa Proce...

Page 17: ...a pompa deve essere alimentata da un circuito dotato di un dispositivo DDR di corrente differenziale di funzionamento assegnato non superiore a 30mA Rivolgetevi ad un elettricista qualificato 3 Contro...

Page 18: ...ll arresto automalico della pompa 3 A tale scopo utilizzate l attacco rapido previsto situato sulla parte superiore della pompa Regolate il cavo alia lunghezza desiderata 4 4 Messa in funzione Nota Ve...

Page 19: ...ommersa deve obbligatoriamente essere immersa prima di avviarla Installare la pompa nell acqua quindi lasciar il tempo di evacuare l aria bolle d aria e soltanto dopo potete collegarla In funzionament...

Page 20: ...con un panno morbido e proprio Non utilizzare prodotti pulitori aggressiva solventi detersivi n di spugna abrasiva n di oggetti affilati o aguzzi 6 2 Ricerca guasti Non tentate mai di smontare la pomp...

Page 21: ...01MC3 516426 Mod le Type Model Type Modello Q800103 3P QSB JH 800103 Alimentation Voltage frequency Tensione 230V 50Hz Puissance Power Potenza 800W Capacit de refoulement Delivery capacity Capacit di...

Reviews: