background image

Page 

10

 / 

19

 

 

 
4.4- Settings 
 

Standby Mode 

 

The pump enter STANDBY mode when the control valve is closed. 

 

The pump stop running automatically.  

 

Water pressure built up in the water discharge pipe. 

 
Operation Mode 

 

The pump enter OPERATION mode when the control valve is open. 

 

The pump start running automatically.  

 

Water pump out of the pipe spout. 

 
Protection Mode 

 

The pump enter PROTECTION mode when water level is lower than the impeller. 

 

The pump stop running automatically.  

 

Reconnect the power to restart the pump. 

 
 

V. OPERATION

 

 
5.1- Intended use 

 

 

The pump is submersible that intended for domestic use. It could be used to remove water 
from flooded premises or pumping water out of well or cellar. It is not intended for 
commercial, artisanal and/or industrial uses. 

 

The pump is designed to work in clear water with suspended particle size not more than 
5mm. 

 

The pump is designed to work in water temperature not exceeding 35°C.  

 

The pump is fully submersible, the immersion depth must not exceed 7 metres (refer to 
Table 1). 

 

Do not use the product in any way other than those stated for intended use. 

 

 

WARNING! Do not use with below liquids 
-  flammable, corrosive or explosive liquids 
- sewage, dirty water or toilet waste water 
- oil or grease 

 

5.2- Operation: 
 

Connecting Carrying Rope (not included) 

 

Attach and secure a rope, which is strong and long enough, to the carrying handle. 

 

Connecting Pressure Hose (not included) 

 

Attach and secure a suitable pressure hose to the pipe spout (refer to Fig. 1 for information).  

 

When plumbing is used, ridig pipe and check valve should be used to prevent water from 
flowing back. 

 

Submerging in Water 

 

Close the control valve. 

Summary of Contents for 511736

Page 1: ...R PUMP User and maintenance manual Original instructions IT POMPA AD ACQUA SOMMERSA AUTOMATICA Manuale di istruzione e di manutenzione Traduzioni delle istruzioni originali R f Art Nr PRPVF500AUTO 511...

Page 2: ...perating this appliance Incorrect operation may cause injury and or damages Please keep this manual for future reference Note Non contractual information and photos which may be changed without prior...

Page 3: ...instructions pour pouvoir s y reporter ult rieurement Conserver ce manuel port e de main pour toute r f rence ult rieure Laisser le manuel avec le produit par ex lors de son utilisation lors de son p...

Page 4: ...ion Ne faites jamais fonctionner une pompe surchauff e Si votre pompe surchauffe teignez la imm diatement et laissez la refroidir N utilisez jamais une pompe dans un environnement inflammable explosif...

Page 5: ...Usage destin La pompe est submersible et destin e un usage domestique Elle peut tre utilis e pour vacuer l eau des locaux inond s ou pour pomper l eau des puits ou des caves Elle n est pas destin e d...

Page 6: ...ous que tous les joints sont solidement connect s N immergez pas la pompe une profondeur sup rieure 7 m tres ce qui pourrait endommager le produit Ne laissez pas la pompe fonctionner sans surveillance...

Page 7: ...laissez la refroidir avant de red marrer Turbine bloqu e Supprimer le blocage et red marrer la pompe La pompe d marre et s arr te fr quemment Fuite ou colmatage interne Remplacer le tuyau et les join...

Page 8: ...it later whenever any questions arise Always be sure to include this manual when selling lending or otherwise transferring the ownership of this product Symbols Explanation of symbols appearing on th...

Page 9: ...a pump in a flammable explosive or corrosive environment 3 3 Special warnings when using this product The pump is suitable for clean water only not for domestic sewage or water containing solid partic...

Page 10: ...rcial artisanal and or industrial uses The pump is designed to work in clear water with suspended particle size not more than 5mm The pump is designed to work in water temperature not exceeding 35 C T...

Page 11: ...E WARNING Before any intervention on product disconnect from power source Reminder In order to maintain the machine in good working condition carry out regular maintenance of the machine after each us...

Page 12: ...ipe hose and joints clean blockage The pump runs but no or little water flow Insufficient water lower than impeller Change working location or position before restart the pump Pipe or hose bent or dam...

Page 13: ...futura Tenere questo manuale a portata di mano in modo da poter far riferimento in un secondo momento in caso di dubbi Assicurasi di includere questo manuale in caso di vendita prestito o in ogni alt...

Page 14: ...tenze per l uso sicuro dell elettroutensile La pompa adatta solo per acqua pulita non per acque reflue domestiche o acqua contenente particelle solide o liquido corrosivo infiammabile Non utilizzare l...

Page 15: ...gianali e o industriali La pompa progettata per funzionare in acque limpide con particelle di dimensioni sospese non superiori a 5 mm La pompa progettata per funzionare a temperature dell acqua non su...

Page 16: ...causare danni al prodotto Non lasciare la pompa in funzione incustodita Non utilizzare la pompa quando persone o animali domestici sono in acqua VI PULIZIA E CONSERVAZIONE AVVERTIMENTO Prima di quals...

Page 17: ...muovere il blocco e riavviare la pompa La pompa si avvia e si arresta frequentemente Perdite o intasamenti interni Sostituire il tubo che perde il tubo flessibile e i giunti pulire l ostruzione La pom...

Page 18: ...ions Foto e illustrazioni senza valore contrattuale PRPVF500AUTO Fig 1 Fig 2 Fig 3 Pos FR EN IT 1 Embout du tuyau G3 4 Pipe spout G3 4 Bocca di erogazione G3 4 2 Vanne de contr le Control valve Valvol...

Page 19: ...Description Descrizione POMPE VIDE FUT AUTOMATIQUE AUTOMATIC SUBMERSIBLE WATER PUMP POMPA AD ACQUA SOMMERSA AUTOMATICA R f rence Reference Articolo PRPVF500AUTO 511736 Mod le Type Model Modello Q55011...

Reviews: