Ribimex 511696 User And Maintenance Manual Download Page 16

Page 

16

 / 

25

 

 

5.2.1- Water parameters 
Here are the operating settings for this pump: 
After 10 seconds, in the condition of no water or when water level is below 40mm, the pump stops 
operating.   
Then the pump will try to detect the presence of water and restart working, if it detects any water which 
level is higher than 40mm, the pump will re-start 
The re-start up settings are as follow:   
After 6 seconds (1 time),   
After 30 seconds (1 time),   
After 10 minutes (1 time),   
After 1 hour (1 time),   
After 5 hours (1 time),   
After 24 hours (1 time),   
If the pump does not detect water, the pump will stop automatically 10 seconds after the re-start up. 
After 24 hours, the pump will repeat over the same re-start up and stop cycle. 
 
5.2.2- Pressure parameters 
The pump starts operating as soon as it is connected to the electricity supply, when water is still detected 
after 10 seconds, the pump will keep operating.   
When the pump pressure reaches the Max pressure setting (the internal pump pressure is over 3.5-4.0bar), 
or when there is no water coming out from the outlet, the pump stops working automatically.   
When the pump pressure is lower than the Min. pressure setting (the internal pump pressure is lower than 
1.5 bar), the pump starts operating again. 

 

Warning! 
Never operate the pump without water (dry running). 
The pump is not designed for continuous operation! (e.g. continuous water circulating operation). 
The submersible pump must be immersed before switching on. 
Place pump into water, then let it purge the air (air bubbles) then only you can connect it. 
 
Important advice 
Sand and other abrasive substances increase wear and tear and reduce the pump's performance. 
Do not use the pump in such environment. 
 

VI. MAINTENANCE AND STORAGE

 

 

 

Before any intervention on product, ensure that product is disconnected from its power source. 

 
6.1- Maintenance 

- In winter, the pump must be carefully drained or placed in “frost” protected condition. 
- Regularly rinse with clear water pump, including the suction line. 
- Avoid pumping liquid containing abrasive materials such as sand. 
- Before restarting, make sure of the good condition of every part of the pump. 
- Clean plastic parts with a clean, soft cloth. 
- Do not use aggressive cleaning product (solvents, detergents) or abrasive sponges or sharp or pointed 
objects. 
ATTENTION: This pump is intended for clean water and is equipped with a filter sponge, in the bottom, 
to filtrate the particles. It is therefore recommended that the filter sponge be cleaned very often. 

Summary of Contents for 511696

Page 1: ...PUMP 1200W WITH INTEGRATED AUTOMATIC CONTROL FLOAT SWITCH User and maintenance manual IT POMPA MULTICELLULARE SOMMERGIBILE 1200W CON CONTROLLO AUTOMATICO GALLEGIANTE INTEGRATI Manuale di istruzioni e...

Page 2: ...mpes ne sont pas destin es pomper de l eau potable I NOMENCLATURE 1 Poign e 2 C ble d alimentation 3 Connecteur 4 Port sortie refoulement 5 Corps de pompe 6 Trous d aspiration Fig 1 II CARACTERISTIQUE...

Page 3: ...e l environnement de l aire de travail Garder l aire de travail bien clair e lumi re naturelle ou artificielle suffisante Garder l aire de travail bien ventil e Ne pas utiliser le produit s il y a ris...

Page 4: ...ion de rallonge Lorsque le produit est utilis avec une rallonge n utiliser que des rallonges con ues et pr vues pour supporter le courant alimentant le produit 16 Rester vigilant Surveiller ce que vou...

Page 5: ...ment vers l appareil ou d autres composants lectriques Danger de mort par lectrocution 9 Placer la rallonge de telle mani re qu elle ne puisse entrer en contact avec un quelconque liquide 10 Ne pas in...

Page 6: ...en vigueur et par du personnel qualifi En cas de doute nous vous conseillons de vous adresser un lectricien La canalisation fixe laquelle sera raccord e la pompe doit comporter un dispositif de s para...

Page 7: ...st une pompe submersible destin e un usage domestique Elle n est pas pr vue pour des applications artisanales industrielles et ou commerciales par ex dans des parcs publics terrains de sport 2 La pomp...

Page 8: ...e pression La pompe commence fonctionner lorsque elle est reli e l lectricit si de l eau est toujours d tect e apr s 10 secondes la pompe continuera de fonctionner Lorsque la pression de la pompe atte...

Page 9: ...lectrique Le flotteur ne d marre pas V rifier l alimentation lectrique Mettre le flotteur en position haute Pas de d bit Filtre sale ou port d aspiration obstru Tuyau de refoulement pli Nettoy le fil...

Page 10: ...ce of swimming pools This pump is not intended for pumping drinking water I PARTS LIST 1 Handle 2 Power cord 3 Connector 4 Discharge port 5 Pump body 6 Suction port Fig 1 II CHARACTERISTICS Descriptio...

Page 11: ...ent Keep work area well lit natural light or sufficient artificial lighting Keep work area well ventilated Do not use product where there is risk to cause fire or explosion in the presence of flammabl...

Page 12: ...common sense Do not operate product when you are tired under the influence of alcohol prescription medicines or drugs 17 Check damaged parts Before further use or reuse of the product it should be car...

Page 13: ...e 12 As a general rule repairs are only to be carried out by an electrician If repairs are performed improperly there is danger of liquid getting into the electronic components of the device 13 Symbol...

Page 14: ...milar qualification in order to avoid any danger a Make sure that the power supply corresponds with the connection specifications of the device see rating label b Check that the power cable is not dam...

Page 15: ...rounds 2 The pump is designed for routine household uses such as gardening irrigation systems pumping water from tanks well It can be used to suck up clear water from flooded premises with particles i...

Page 16: ...re setting the internal pump pressure is lower than 1 5 bar the pump starts operating again Warning Never operate the pump without water dry running The pump is not designed for continuous operation e...

Page 17: ...sieve Clean pump and replace worn out parts Pump switches of after short operating period Dirty water thermal cut out stops pump Water too hot thermal cut out stops pump Remove mains plug Clean pump a...

Page 18: ...pa non prevista per il pompaggio dell acqua di consume I ELENCO COMPONENTI 1 Maniglia 2 Cavo elettrico 3 Connettore 4 Bocca di scarico 5 Corpo pompa 6 Fori di aspirazione Fig 1 II CARATTERISTICHE Desc...

Page 19: ...Il disordine nell area di lavoro aumenta il rischio di incidenti 2 Tenere conto dei fattori circostanti di influenza Accertarsi che l illuminazione sia buona luce del sole o illuminazione artificiale...

Page 20: ...pportare la corrente che alimenta l attrezzo 16 Fare sempre attenzione Guardare quello che si fa Procedere con giudizio Non utilizzare l utensile se non si concentrati si stanchi o sotto l influenza d...

Page 21: ...e la macchina se persone o animali sono in acqua o in contatto con i tubi 11 Non lasciare incustodito l apparecchio Scollegare l alimentazione durante i periodi di non utilizzo o durante una lunga ass...

Page 22: ...e sostituito dal costruttore dal personale del relativo servizio di post vendita o da personale con qualifiche simili per evitare qualunque tipo di rischio a Verificare che l alimentazione di rete cor...

Page 23: ...mestico La pompa non destinato ad applicazioni artigianli industriali e o commerciali ad esempio nei parchi pubblici campi sportivi 2 La pompa progettata per l utilizzo domestico quotidiano in applica...

Page 24: ...ore 5 2 2 Pressione La pompa inizia a funxionare quando collegata all elettricit se viene ancora rilevato acqua dopo 10 secondi la pompa funzioner Quando la pressione della pompa raggiunge l impostaz...

Page 25: ...e elettrica Il galleggiante non si avvia Controllare l alimentazione elettrica Mettere il galleggiante in posizione alta Nessuno scarico Filtro o fori di aspirazione intasato Tubo di scarico piegato P...

Reviews: