29
EN16005 ELECTRIC CONNECTION
LED + -
30 29 28
2
code ACG9442 - code ACG9443 - code ACG9444
LED BAR
brown
white
yellow
green
CONNECTION OF 2 RADAR FOR COMMAND AND SAFETY (ACG9560) AND 1 RADAR FOR SAFETY (ACG9459) FOR 1 DOOR WITH ACTIVE AUTOTEST (PARAMETER P=1)
NOTE: A POSSIBLE STOP PUSH-BUTTON MUST BE CONNECTED IN SERIES TO THE PINK WIRE OF THE RADAR FOR SAFETY (ACG9459)
STOP
ACG9460 RADAR
FOR COMMAND AND SAFETY
ACG9460 RADAR
FOR COMMAND AND SAFETY
GREEN
GREY
WHITE
INTERNAL
EXTERNAL
YELLOW
YELLOW
WHITE
PINK
BROWN
RED
BLUE
ACG9459 RADAR FOR SAFETY
WHITE AND YELLOW WIRES
NOT CONNECTED
GREEN
GREY
PINK
BROWN
RED
BLUE
GREEN
GREY
PINK
BROWN
RED
BLUE
CONNECTION OF 2 RADAR FOR COMMAND AND SAFETY (ACG9560) FOR 1 DOOR WITH ACTIVE AUTOTEST (PARAMETER P=1)
NOTE: IF STOP PUSH-BUTTON IS NOT PRESENT, CONNECT TERMINAL 18 WITH TERMINAL 8
ACG9460 RADAR
FOR COMMAND AND SAFETY
ACG9460 RADAR
FOR COMMAND AND SAFETY
STOP
GREEN
GREY
WHITE
INTERNAL
EXTERNAL
YELLOW
YELLOW
WHITE
PINK
BROWN
RED
BLUE
GREEN
GREY
PINK
BROWN
RED
BLUE
2.5 m
20 cm
2.5 m
20 cm
ACG9460
ACG9459
2.5 m
ACG9460
20 cm
Requested to protect
movement of the leaf which
opens against a side wall.
Code ACG9460
CONNECTION OF 2 RADAR FOR COMMAND
AND SAFETY (ACG9560) FOR 1 DOOR WITH
ACTIVE AUTOTEST (PARAMETER P=1)
NOTE: IF STOP PUSH-BUTTON IS NOT PRESENT,
CONNECT TERMINAL 18 WITH TERMINAL 8.
TO SELECT PARAMETER P=1 (PHOTOTEST ACTIVATED)
YOU NEED TO HAVE THE LCD PROGRAMMER AVAILABLE
AT LEAST DURING THE PROGRAMMING OF THE DOOR
code ACG9418 (FOR RECESS) - code ACG9419 (FOR
WALL).
Code ACG9459 - ACG9460
CONNECTION OF 2 RADAR FOR COMMAND
AND SAFETY (ACG9560) AND 1 RADAR
FOR SAFETY (ACG9459) FOR 1 DOOR WITH
ACTIVE AUTOTEST (PARAMETER P=1)
NOTE: A POSSIBLE STOP PUSH-BUTTON MUST BE
CONNECTED IN SERIES TO THE PINK WIRE OF THE
RADAR FOR SAFETY (ACG9459).
TO SELECT PARAMETER P=1 (PHOTOTEST ACTIVATED)
YOU NEED TO HAVE THE LCD PROGRAMMER AVAILABLE
AT LEAST DURING THE PROGRAMMING OF THE DOOR
code ACG9418 (FOR RECESS) - code ACG9419 (FOR
WALL).
G
B
Summary of Contents for SLIDER 120
Page 12: ...12 KIT ELETTROBLOCCO CENTRALE cod ACG9454 15 COLLEGAMENTO ELETTROBLOCCO I ...
Page 24: ...24 KIT ÉLECTROBLOCAGE CENTRALE code ACG9454 15 RACCORDEMENT ÉLECTROBLOCAGE F ...
Page 36: ...36 KIT CENTRAL ELECTRIC LOCK code ACG9454 15 ELECTRIC LOCK CONNECTION G B ...
Page 48: ...48 KIT ELECTROBLOQUEO CENTRAL còd ACG9454 15 CONEXIÓN ELECTROBLOQUEO E S ...
Page 52: ...52 ...