a  pedestrian  crossing.  In  fact,  the  Pedestrian  command  (see  Point  F)  is  carried  out 
only by opening the motor M1 just enough for a pedestrian to pass, as described into 
the Point F procedure.
From  the  Pedestrian  opening  position  the  Automatic  Closing  can  be  enabled  or 
disabled with DIP3. 
From  the  Pedestrian  opening  position,  the  gate  can  be  completely  opened  by  the 
OPEN or by the K BUTT button or by the RADIO button.

AUTOMATIC CLOSING (from the COMPLETE open position)

The Automatic Closing from the complete open position can be enabled turning ON 
the DIP3.
The maximum gap of time that can be programmed is 5 minutes (see Point D and E).

AUTOMATIC CLOSING (from the PEDESTRIAN open position)

The Automatic Closing from the pedestrian open position can be enabled turning ON the 
DIP3. The maximum gap of time that can be programmed is 5 minutes (see Point F).

ELECTRIC LOCK (LOCK  A+) command

The DIP 8 in the ON position enables the Electric Lock (MAX 15W 12V) command. The 
Electric Lock (LOCK A+) will be automatically turned ON each time the gate opens. If 
the DIP8 is OFF, the Electric Lock command is DISABLED. 
The Electric Lock remains active for 1,5 seconds.

MANUAL RELEASE FACILITY

The 

DIP 9

 in the ON position enables the Manual Release Facility. Once the gate has 

completely  closed,  a  short  reversal  manoeuvre  (0.2  seconds)  will  be  done    to  ease 
manual release.

ELECTRIC LOCK unlocking FACILITY

The 

DIP 9

 in the ON position enables the Electric Lock unlocking Facility. From close 

position,  just  before  opening,  the  gate  will  perform  a  short  closing  manoeuvre  (0.5 
seconds) to ease unlocking from electric lock.

ELECTRIC LOCK coupling FACILITY

The 

DIP 10

 in the ON position enables the Electric Lock coupling Facility. Once the gate 

has  closed, a short hammering close pulse (0.5 seconds) will be done at full power to 
guarantee the electric lock or mechanical bolt coupling. 

F

UNCTIONING OF SAFETY ACCESSORIES

PHOTOCELL (PHOT - COM)

In case the switch DIP4 is in the OFF position, the photocells are active both in gate 
opening  and  in  gate  closing.  In  this  configuration,  if  an  obstacle  cuts  the  photocell 
beam:
- while the gate is closing, the gate will open
-  while the gate is opening, the gate will stop and will restart opening when the obstacle 

is removed

- while the gate is still, it will not move neither in opening nor in closing.
In case of the switch DIP4 is in the ON position, the photocells are active only in gate 
closing. 
In this configuration, if an obstacle cuts the photocell beam:
- while the gate is closing, the gate will open
- while the gate is opening, the gate will continue open
-  while the gate is still, it will open if a open command is request, it will remain still if a 

close command is request.

The photocell input (PHOT - COM) is a NORMALLY CLOSED contact. 
In  case  there  are  more  couple  of  photocells,  the  contacts  from  all  the  photocell 
receivers must be connected in series.
In case the photocells are not installed, this contact must be short circuited with a wire 
jump (from PHOT to COM) to permit the gate to operate.

ATTENTION:  In  case  the  receiver  led  remains  lit, 
malfunctioning of the main supply is suspected. 
It  is  advisable  to  connect  electrically  to  earth  the 
columns or the photocells stands to the terminal D-, to 
shield the photocells from external noise.
Be  careful  not  to  short  circuit  the  system  when  the 
supply phases are inverted!

AUTOMATIC CLOSING AFTER THE TRANSIT THROUGH THE PHOTOCELL

This option could be useful to close automatically the gate when the vehicle left and 
disengaged the photocell beam. If the DIP12 is turned ON, this function is activated and 
the PHOTO input will have two purposes:
-  detect  the  obstacle  and  prevent  the  gate  movement  in  according  with  the  DIP4 

position;

- close the gate as soon as the vehicle leaves the photocell beam.

If DIP12 ON and DIP4 OFF 

If the gate is opening and a vehicle crosses the photo beam, the gate will stop. When 
the vehicle leaves, the gate will close automatically after 1 second pause.

If DIP12 ON and DIP4 ON 

If the gate is opening and a vehicle crosses the photo beam, the gate will continue to 
open. When the vehicle leaves, the gate will stop and then closes automatically after 
1 second pause.

If  the  complete  gate  open  position  is  reached  before  the  vehicle  leaving,  the 
DIP12 will be ignored and the automatic closing will be managed in according 
to the DIP3 position.
PAY ATTENTION:

  it  is  highly  recommended  to  check  photocells  operation  at  least 

every 6 months.

SAFETY STRIP (EDGE - COM)

If an obstacle presses the safety strip:
- while the gate is still, it will not move neither in opening nor in closing
- while the gate is closing, the gate will open
- while the gate is opening, the gate will close.
In case the safety strip is held pressed a further quick reversion, after 2 seconds, is 
performed. The gate interrupts any movement and this alarm state is indicated by 1 
minute Blinker flashing. The normal gate operations can be restored by pressing any 
push button or radio commands. 
The safety strip input (EDGE - COM) is a NORMALLY CLOSED contact. 
In case there are more than one safety strip, all their contacts must be connected in 
series.

In case the safety strip is not installed, this contact must be short circuited with a 
wire jump (from EDGE to COM) to permit the gate to operate and the Safety Strip 
test must be disabled (DIP 13 OFF).

FUNCTIONING IN DEAD MAN MODE WHEN THE SAFETY DEVICES ARE FAILING

If the safety edge fails or remains engaged for more than 5 seconds, or if photocell 
fails or remain engaded for more than 60 seconds, the K BUTTON and PEDESTRIAN 
commands will work only in dead man mode.
The  signal  that  this  mode  has  been  activated  is  given  by  the  blinking  of  the 
programming led.
With  the  blinking  of  the  programming  led,  the  opening  and  closing  operation  are 
allowed only with the command button pressed and held. The radio commands and 
that of automatic closing, will be excluded, since their use in this mode, is not allowed 
by the norms.
Once the failing safety device is repaired,  in automatic after 1 second, all standard 
commands that were selected, such as step by step, automatic mode, radio commands 
and automatic closing start functioning again.

Note 1:

  during  this  functioning  in  dead  man  mode,  in  case  of  damage  to  the  safety 

strips (or photocells) the photocells (or safety strips) still work by interrupting 
the operation in progress.

During the dead-man operation, press and hold the K BUTTON or the PED BUTTON 
for the complete operation, and until the switching off of the leds of the motors (DL3 
-  DL5  total  opening  M2  -  M1  -  pedestrian  DL5  -  DL4  -  DL6  total  closing  M2  -  M1  - 
pedestrian DL6), or of the blinker, when installed.

The dead-man operation is only an emergency operation which must be activated 
for a very short period and with the complete installation at sight so to have a 
secure and safe control of the system. As soon as possible however, the failing 
safety devices must be repaired and activated.

TESTING THE SAFETY STRIP equipment 

The switch DIP13 ON enables to test the safety strip equipment. The test is performed 
every time the gate completes a full opening. The test is available 

only if the safety 

strip device is equipped with a dedicated power supply input.

In fact, the safety strip equipment power supply input can be connected to the D+TEST 
and  D-  outputs  (DIP13  ON).  Automatically,  every  time  the  gate  completes  a  full 
opening, just before closing, the control board switches OFF the D+TEST and D- power 
supply output for a very short time. While the safety strip power supply is switched OFF, 
if everything is working fine the safety strip contact (EDGE - COM) must open. In case 
the test fails, no other gate manoeuvre will be allowed. 
NOT  ALL  THE    SAFETY  STRIPS  CAN    BE  TESTED,  THUS  THE  SWITCH  DIP13 
MUST BE LEFT OPEN.
 

BLINKER

Connect the flashing light to the blinker output, use flashing lights ACG7059 and bulbs 
of 40W maximum.

PRE-FLASHING function

The DIP 5 in the ON position enables the pre-flashing, the BLINKER starts flashing 3 
seconds before every movement of the gate.

12Vdc

Term.
D-

Summary of Contents for R50

Page 1: ...code code R50 230V 50 60Hz AA21580 Peso max cancello Poids maxi portail Max gate weight Max Torgewicht 2000 kg 4460 lbs ITALIANO pag 04 FRANÇAIS pag 14 ENGLISH page 24 DEUTSCH pag 34 OPERATORE PER PORTONI INDUSTRIALI OPERATEUR POUR PORTAILS INDUSTRIELS OPERATOR FOR INDUSTRIAL DOORS TORANTRIEB FÜR INDUSTRIETORE ...

Page 2: ...E SAFETY OF THE PEOPLE IT IS IMPORTANT TO FOLLOW ALL THE INSTRUCTIONS INSTALLATIONSVORSCHRIFTEN BEACHTET WERDEN 1 Wenn nicht bereits an der elektrischen Schaltzentrale vorgesehen muss vor der Schaltzentrale ein thermomagnetischer Schalter installiert werden omnipolar mit einer minimalen Kontaktöffnung von 3 mm der ein von den internationalen Normen anerkanntes Konformitätszeichen besitzt Solch ein...

Page 3: ...pring Measurements in mm TECHNICAL DATA Max leaf length Max leaf weight Average opening time 90 Operating speed EEC Power supply Motor capacity Power absorbed Capacitor EEC Power supply Motor capacity Power absorbed Capacitor 230 50 60 Normative cycles 120 60 Normative cycles Daily cycles suggested Service Consecutive cycles guaranteed Grease Actuator weight Operating temperature Protection grade ...

Page 4: ...lide on the ground during operation turn the set screw on the spring clockwise to increase the pressure between the wheels and the ground To reduce wheel wear during operation loosen nuts D with a No 13 wrench and tilt the rubber wheels so that the axles coincide with the center of the gate leaf pivot point The wheels may be tilted by 0 to 7 5 Retighten the two nuts The R50 is equipped with two wa...

Page 5: ... these appropriate handles are placed so to avoid safety risks for the operator That the physical effort necessary to move the gate leaf should not be higher than 225 N for doors gates for private dwellings and 390N for doors gates for commercial and industrial sites values indicated in 5 3 5 of the EN 12453 norm A Maximum stroke 60 mm during movement holes or uneven ground B Remove the elastic pi...

Page 6: ... surfaces carefully once a week Check wheel ground pressure and condition of motor wheels every six months The motor should be overhauled every two years and the oil replaced ELECTRIC CONNECTIONS T2 code BC07086 T2 CRX code BC07085 AERIAL COAX R 2 2KΩ SIGNAL BUZZER 12Vdc for AUTOTEST EDGE 12Vdc for ACCESSORY SUPPLY PHOTOCELL EDGE K BUTTON PED BUTTON COM CAPACITOR M1 POWER SUPPLY MOTOR 1 MOTOR 2 CA...

Page 7: ...HASE AND CAPACITOR CONNECTIONS MOTOR 1 COMMON CONNECTION MOTOR 1 PHASE AND CAPACITOR CONNECTIONS DO NOT REMOVE ANY JUMPER OTHERWISE THE OPERATOR WILL NOT WORK only CRX control board DO NOT REMOVE ANY JUMPER OTHERWISE THE OPERATOR WILL NOT WORK Not available for R50 Built in radio module model CRX or connector for radio receiver RIB 12 Vdc supply To select 1 motor M1 or 2 motors M1 and M2 Programmi...

Page 8: ...d lock again the operators 2 Turn DIP1 to ON position The red LED DL1 starts blinking 3 Press the PROG button and hold it When GREEN LEDS DL3 and DL5 are on the gate leaves are opening with a phase shift of 2 seconds Check the leaves swinging and the opening mechanical stopper position movement is now performed in man present mode open close open etc If any of the leaf closes instead of opening re...

Page 9: ...e DL2 LED green will flash once 4 The code programming time resets automatically so that you can programme the next remote control 5 To finish programming let 10 seconds pass and then press the PROG button briefly The red DL1 LED will stop flashing 6 Reposition DIP 1 to OFF and DIP 3 to OFF N B IF THE DL1 LED CONTINUES TO FLASH RAPIDLY THIS MEANS THAT DIP 1 IS STILL POSITIONED TO ON AND ANY MANOEU...

Page 10: ...leaves the gate will close automatically after 1 second pause If DIP12 ON and DIP4 ON If the gate is opening and a vehicle crosses the photo beam the gate will continue to open When the vehicle leaves the gate will stop and then closes automatically after 1 second pause If the complete gate open position is reached before the vehicle leaving the DIP12 will be ignored and the automatic closing will...

Page 11: ... out a self check at the beginning of each operation During blackout At the return of the network power supply If the gate is totally closed It will remain closed If the gate is at the opening stage It will continue opening If the gate is totally open with dip 3 OFF It remains open Consequently closing operations of the gate can be controlled If the gate is totally open with dip 3 ON It remains op...

Page 12: ...TTER code ACG8028 for more than 2 photocells couples up to 4 COUPLE OF BUILT IN BOXES FOR THE FIT SYNCRO code ACG8051 CODE LEARNIG SYSTEM RADIORECEIVERS RX91 A quarzata and coupling code ACG5005 RX91 A quarzata and terminal board code ACG5004 RX433 A super eterodyne and coupling code ACG5055 RX433 A super eterodyne and terminal board code ACG5056 RX433 A 2CH super eterodyne 2 channel and coupling ...

Page 13: ...245 Rotore con albero CMO1320 Statore 230V 50 60Hz 1P CCM6302ZZ Cuscinetto 6302ZZ CTC1006 Chiavetta 6x6x20 CTC1069 Molla per R50 CTC1104 Paraolio 50x72x10 CTC1124 Seeger E28 CTC1136 Seeger I 80 CTC1206 Molla a tazza CTC1350 Anello di tenuta Codice Denominazione Particolare CTC1401 Paraolio 50x80x8 CTC1402 Paraolio30x47x7 CVA1029 Manopola MCG 28 85 GIR CVA1380 Copriventola motore CVA1381 Ventola CV...

Reviews: