background image

5

will be completely extended. Same result will be attained depressing the open pushbutton 
following elapsing of alarm time.

WIND ALARM MODE

The control panel is provided with an inlet port for wind speed monitoring through an 
anemometer.
Such function helps preventing the awning being damaged by strong wind gusts: in such 
instance the control unit gets in wind alarm mode, retracting the awning.
-  During the alarm sequence, the led M1 indicates the alarm flashing. The alarm phase 

lasts about 7 minutes.

-  On elapsing of the 7 minutes cycle, in case the wind speed has decreased below the 

alarm treshold, the awning is extended to the position attained before the alarm triggering 
(automatic re-extension function). In case the wind speed still exceeds the alarm treshold, 
the awning maintains the retracted position until ceasing of alarm condition.

-  In case two-position change over switches are installed, set to open, on elapsing of 7 

minutes the awning will be fully extended (in case the... are set close, the awning will not 
be extended).

-  It is possible to set the wind alarm treshold through the setting trimmer. Rotating the 

cursor clockwise, a higher wind speed will be required to trigger the alarm.

-  During the installation it is possible to remove the 7 minutes waiting time. To do so 

shortly depress the LEARN pushbutton.

NOTE:

 in case that the control unit is on the closing position and, through a manual 

moving, the automation is brought to the opening position, an intervention of the sensor will 
not command a closing of the automation, bacause the control unit is still under the closing 
position.

TECHNICAL DATA

 

Supply voltage 

230 Vac +10% - 15%

Motor outlet 

230 Vac 500W MAX cos  > 0,8

Card consumption  

4W MAX (excluding accessories and utilities)

Motor time work 

7 minutes

Stand by time following wind alarm 

7 minutes

Operating temperature 

-10°C ÷ +60°C

Protection Grade 

IP54

NOTE:
IN CASE OF BLACK-OUT, ON THE FIRST WIND ALARM THE AWNING RETRACTS, 
WITHOUT FURTHER RE-OPENING
-  The mode of operation of the control unit wind alarm is controlled through 

setting of DIP 2.

-  Alarm mode prevails over any other mode of operation/control.
-  To attain a proper extension of the awning following ceasing of alarm 

condition, operate as follows:

-  Fully close (reract) the awning through the pushbutton CHIUDI.
-  Switch off the main supply to the control unit, wait about 5 seconds, then 

switch the supply on.

SETTING OF TRAVEL STOPS AND OPERATION TIME

The extension and retraction stroke ends can be set by adjusting the travel end stops of the 
motor.
The control unit is programmed with a 7 minutes maximum operating time, to provide a 
safety stop of the motor in case of malfunction of the travel end stops.

CONNECTION OF SEVERAL CONTROL PANELS TO ONE AMEMOMETER

It’s possible to connect up to 6 control panels to one anemometer. 
It’s reccomandable to use a shielded cable and to set the anemometer so that the cables 
go to the shortest way to the control panels.
Follow the cabling diagram as underlined in the figure.

With a wind sensor used with 

ONE

 control panel, 

leave closed

 the 

expansion jumper of the wind sensor.

With a wind sensor used with 

THREE

 control panels, 

leave closed

 

the expansion jumper of the wind sensor of the first control panel and 

remove

 the one present in the second and in the third control panel.

With a wind sensor used with 

SIX

 control panels, 

leave closed

 the expansion jumper of the wind sensor of the first 

control panel and 

remove

 the one present in the second and in the third, fourth, fifth and sixth control panel.

ANTENNA

COM

OPEN (N0)

CLOSE (N0)

1

3

5

2

JUMPER CLOSED

WIND

SENSOR

CP 1

4

6 7

ANTENNA

COM

OPEN (N0)

CLOSE (N0)

1

3

5

2

JUMPER OPEN

CP 2

4

6 7

ANTENNA

COM

OPEN (N0)

CLOSE (N0)

1

3

5

2

JUMPER OPEN

CP 3

4

6 7

ANTENNA

COM

OPEN (N0)

CLOSE (N0)

1

3

5

2

JUMPER OPEN

CP 6

4

6 7

CP= CONTROL PANEL

CP 1

CP 1

CP 2

CP 3

CP 4

CP 5

CP 6

CP 1

CP 2

CP 3

G

B

Summary of Contents for MINI TS SV

Page 1: ...code ACG2266 MINI TS SV QUADRO DI COMANDO PER 1 MOTORE A 230 Vac PER TENDE DA SOLE ONE 230Vac MOTOR CONTROL PANEL FOR SUNSHADES ITALIANO pag 02 ENGLISH page 04 2nd edition ...

Page 2: ...i lavoro fisso 7 min Analogamente premendo per un breve istante il pulsante di chiusura si otterrà la chiusura completa del serramento fino alla fine del tempo di lavoro Se viene premuto per un breve istante il pulsante Apri o Chiudi durante una fase di movimento si otterrà un arresto del moto del serramento DIP 2 OFF In questa modalità di funzionamento dopo un allarme vento il quadro elettronico ...

Page 3: ...P54 manuale l automatismo venga portato in apertura un intervento del sensore non farà richiudere la tenda in quanto il quadro di comando si trova ancora nello stato di chiuso NOTA BENE IN CASO DI BLACK OUT AL PRIMO ALLARME VENTO LA TENDA VIENE RICHIUSA E NON SI RIAPRE Il comportamento dell allarme vento del quadro elettronico è condizionato dall impostazione del DIP 2 L intervento dell allarme ha...

Page 4: ...ning will fully retract until the expiring of travel time In case the pushbutton open close is shortly depressed during awning movement the system will stop DIP 2 OFF In this mode of operation following a wind alarm the control unit will retract the awning After 7 minutes it will be possible to open the awning through the pushbutton or a two position change over switch set open In case of a furthe...

Page 5: ... temperature 10 C 60 C Protection Grade IP54 NOTE IN CASE OF BLACK OUT ON THE FIRST WIND ALARM THE AWNING RETRACTS WITHOUT FURTHER RE OPENING The mode of operation of the control unit wind alarm is controlled through setting of DIP 2 Alarm mode prevails over any other mode of operation control To attain a proper extension of the awning following ceasing of alarm condition operate as follows Fully ...

Page 6: ...6 NOTES ...

Page 7: ...7 NOTES ...

Page 8: ...it a été complètement développé et fabriqué en Italie This product has been completely developed and built in Italy Artìculo totalmente proyectado y producido en Italia 25014 CASTENEDOLO BS ITALY Via Matteotti 162 Tel 39 030 2135811 Fax 39 030 21358279 www ribind it ribind ribind it automatismi per cancelli automatic entry systems ...

Reviews: