SIMPLIFIED INSTRUCTIONS FOR K400 WITH K 24V-CRX fw. 2018_02_09
1° Connecting the accessories
K400 FCE
K400 FCM
0
24Vdc 20W
24Vac
10Vac
ANTENNA
433 MHz
STOP
24Vdc 0,4A ±15%
24Vdc 0,4A ±15%
TIMER
L.S. OPEN
AND CLOSE
FUSE
T 1,6A
POWER SUPPLY
230Vac 50Hz
TRANSFORMER
ANTENNA BRAIDING
COMMON
PHOTOCELLS
EDGE
OPEN
CLOSE
SINGLE COMMAND
PEDESTRIAN
24Vdc 10W
BACKUP BATTERIES
FOR BATTERY CHARGER
BOARD (OPTIONAL)
A+T
EST / A-
SAFETY DEVICE
AUTO-TEST OR
ENERGY SAVING
(LOW POWER) WITH
BATTERY OPERATION
MANUAL
RELEASE
SAFETY
M
2° Installing and adjusting the limit switch cams
Position the cams at the ends of the rack rail.
Tighten the two screws to secure them in place.
Open the shutter door of the K400.
Insert the key and turn in a clockwise direction.
Pull the lever to unlock the operating system.
Check the cam intervention point by opening and closing the gate.
N.B.: The cams should press the electric micro-switches before the moving part
touches the mechanical stops (K400 FCE). The DL7 and DL8 LEDs switch off
when the cams are detected by the proximity sensor (K400 FCM).
Position the gate halfway and re-secure the operating system.
ITA
ESP ENG FRA GRE DEU RUS ARA THAI BUL FAR TUR HIN
CHI POL HUN CEK KOR