27
G
B
M1
B
OPEN
CLOSE
N
L
OPEN
CLOSE
KEY SELECTOR
PUSH BUTTON
POWER SUPPLY
M2
B =
Electrobrake
CAP =
Capacitor
Connect the power supply cable to the clamps provided.
CAUTION: Make the connections according to the chart below (OPEN button with OPEN
clamp, CLOSE button with CLOSE clamp and connect the direct phase of the power supply
to the COM clamp).
Screw the run stop cover back on.
Verify that the switch is on INS (In this phase the micro-switches do not work and the C1
and C2 run stop cams are automatically regulated).