ATTENTION - FOR THE SAFETY OF PEOPLE IT IS IMPORTANT TO FOLLOW
ALL THE INSTRUCTIONS
KEEP THESE INSTRUCTIONS WITH CARE
1° - If it is not forecast in the electric gearcase, install a switch of magnetothermic
type upstream, (omni polar with minimum port of the contacts of 3mm) with
a check of conformity to the international standards. Such devise must be
protected against the accidental lockup (for example by installing inside a
locked board).
2° - For the section and the type of the cables RIB advices to use a cable of
H05RN-F type with 1,5 sqmm minimum section and, however, to keep to the
IEC 364 and installation standards in force in your country.
3° - Positioning of a possible couple of photoelectric cells: the radius of the
photoelectric cells must be at a height of no more than 70 cm from the
ground and at a distance not superior to 20 cm from the motion plane of the
door
. Their correct working must be verified at the end of the installation in
accordance with point 7.2.1 of the EN 12445.
4° - To fulfil the limits set by EN 12453, and in case the peak force exceeds
the normative limit of 400 N it is necessary to have recourse to the active
presence survey on the whole height of the
door
(up to max 2,5 m) - The
photoelectric cells, in this case, must be applied to the outside and the inside
to a distance from the plan of movement of the door not advanced to
20 cm,
every 60÷70 cm for all the height of the door until to a maximum of
2,5 m (EN 12445 point 7.3.2.1) - es. high door 2,2 m => 6 photoelectric cell
braces - 3 inner and 3 external (6 FIT SYNCRO with 2 TX SYNCRO).
N.B.: The earthing of the system is obligatory.
The data described in this handbook are purely a guide.
RIB reserves the right to change them in any moment.
Carry out the system in the respect of the standards and laws in force.
IMPORTANT SAFETY INSTRUCTIONS
FOR THE INSTALLATION
ATTENTION - THE INCORRECT INSTALLATION
CAN CAUSE SERIOUS DAMAGES
FOLLOW ALL INSTALLATION INSTRUCTIONS
1° - This handbook is exclusively addressed to the specialized personnel who
knows the constructive criteria and the protection devices against the
accidents for motorized gates, doors and main doors (follow the standards
and the laws in force).
2° - The installer will have to issue a handbook to the final user in accordance
with the 12635.
3° - The installer will have to put the tags warning against the entrapping
dangers near the controls and the horizontally pivoted door.
4° - Check frequently the system, in particular cables, springs and supports
to find out possible unbalances, wear signs or damages. The final user
must not operate electrically the horizontally pivoted door if this needs
maintenance or repair, since a failure in the installation or a non correctly
balanced barrier can provoke wounds.
5° - Before proceeding with the installation, the installer must forecast the
risks analysis of the final automatized closing and the and the safety of the
identified dangerous points (Following the standards EN 12453/EN 12445).
6° - Before installing the motion motor, the installer must verify that the door is
in good mechanical conditions and that it adequately opens and closes.
7° - The installer must install the member for the manual release at a height
inferior to 1,8 m.
8° - The installer will have to remove possible impediments to the motorized
motion of the door (eg. Door bolts, sliding bolts, door locks etc.)
9° - The installer will permanently have to put the tags warning against the
deflection on a very visible point or near possible fixed controls.
10° - The wiring harness of the different electric components external to the
operator (for example photoelectric cells, flashlights etc.) must be carried
out according to the EN 60204-1 and the modifications to it done in the
point 5.2.2 of the EN 12453.
11° - Keep the automatism controls (push-button panel, remote control etc.) out
of the children way. The controls must be placed at a minimum height of
1,5 m from the ground and outside the range of the mobile parts.
12° - Before carrying out any installation, regulation or maintenance
operation of the system, take off the voltage by operating on the special
magnetothermic switch connected upstream.
13° - At the end of the installation, the installer will have to make sure that the
parts of the door do not encumber streets or public sidewalks.
14° - At the end of the installation, the installer will have to make sure
that the motion motor prevents or blocks the opening motion when
the door is loaded with a 20 kg weight, fixed in the middle of the
inferior edge of the door.
THE RIB COMPANY DOES NOT ACCEPT ANY RESPONSIBILITY for possible
damages caused by the non observance during the installation of the safety
standards and of the laws in force at present.
IMPORTANT INSTRUCTIONS FOR THE SAFETY
G
B
3
Summary of Contents for BOSS 230V MASTER DX
Page 14: ...14 64 65 66 67 68 69 70 71 72 73 74 I ...
Page 32: ...32 F 64 65 66 67 68 69 70 71 72 73 74 ...
Page 50: ...50 G B 64 65 66 67 68 69 70 71 72 73 74 ...
Page 58: ...NOTES 58 ...