29
G
B
FOR CONTROL PANEL ABLE TO MANAGE A 12/24Vdc MOTOR
-
It is not possible to connect directly MASTER NO TOUCH 868 to the motor power supply output of the control panel because polarities are exchanged in opening and closing
and control panel has slow speed in approaching which is not possible to disengage.
+
-
24Vdc COURTESY LIGHT POWER SUPPLY
OUTPUTS TERMINAL BLOCKS ON CONTROL
PANEL
F
N
*R1
N.O.
N.O.
CONNECT J2 TO POWER SUPPLY LINE 120/230V ON
CONTROL PANEL THOUGHT 1 CONTACT RELAY WITH
120/230V BOBINE MANAGED BY A N.O. COURTESY LIGHT
OUTPUT CLEAN CONTACT ON CONTROL PANEL
POWER SUPPLY LINE
120/230Vac
* R1 =
RELAY WITH 1 CONTACT AND 120/230Vac BOBINE
*R1
+
-
N.O. N.O.
CONNECT J4 TO ACCESSORIES POWER SUPPLY LINE 12/24V ON CONTROL
PANEL THOUGHT 1 CONTACT RELAY WITH 12/24V BOBINE MANAGED BY A N.O.
COURTESY LIGHT OUTPUT CLEAN CONTACT ON CONTROL PANEL
ACCESSORIES
POWER SUPPLY
12/24V
TERMINAL BLOCKS
ON CONTROL PANEL
* R1 =
RELAY WITH 1 CONTACT AND 12/24V
BOBINE
MASTER NO TOUCH 868 CONNECTIONS TO A CONTROL PANEL WITHOUT AN OUTPUT TO SUPPLY A BLINKER
COURTESY LIGHT
TERMINAL BLOCKS
N.O. CLEAN CONTACT
ON CONTROL PANEL