G
B
LAYOUT
J1
DL3
J2
DL4
DL2
DL1
S1
JP2
J3
J4
JP1
BUZZER
J1
=>
COM
=> common in NC contact
CONTACT N.C.
=> usually closed contact to be connected to the Strip or Photocell in the electric control panel
POWER - 12/24 V
=> negative supply 12/24V
POWER + 12/24 V
=> positive supply 12/24V
AUTOTEST
=> supply for AUTOTEST (see also JP1 for the selection)
ALARM N.C.
=> usually closed contact to be connected to the STOP input on the electric control panel
J2
=>
120/230 Vac
TERMINALS TO BE CONNECTED TO THE 120/230V 50/60Hz BLINKER OUTPUT OF THE ELECTRONIC CONTROL PANEL
J3
=>
TERMINAL FOR CONNECTING THE 868,3 MHz ANTENNA
J4
=>
12/24 V
TERMINALS TO BE CONNECTED TO THE 12/24V
BLINKER OUTPUT OF THE ELECTRONIC CONTROL PANEL
PAY CLOSE ATTENTION TO THE POLARITY INDICATED ON THE PRINTED CIRCUIT
JP1
=>
AUTOTEST SUPPLY SELECTION
JP1-
Jumper autotest selection mode with negative supply
JP1+/~
Jumper autotest selection mode with positive supply or AC (for use with RIB panel model J)
JP2
=>
A provision for future implementations
S1
=>
PROG. RX
Programming pushbutton
BUZZER
=>
Signals, through different sounds, possible adjustments to be made during installation and events of warning or alarm
LED
DL1 (bi-colour)
off
=> normal operation
green => photocell engaged
red/green => alarm
DL2 (yellow) - presence of supply voltage 12-24V
DL3 (red)
- N.C. CONTACT
DL4 (red)
- N.C. ALARM
+
-
MASTER NO TOUCH 868
ATTENTION: THE MASTER NO TOUCH 868 CANNOT be installed more than 3 metres away from the control panel of the door operator.