MEMORIZATION
- Set the micro-switch 1 on the MASTER Wi-Fi board on “ON” position to enable the pair of
VERTIGO Wi-Fi photocells to store.
To perform memorization use the following procedure:
-
Push the button
PROG RX
found on the MASTER Wi-Fi card => the dual-colored LED
EDGE PHOT 1 will flash red for 1 minute (the time necessary to perform memorization).
-
Push the button
S3 PROG
on the VERTIGO Wi-Fi receiver (Fig. 5) with micro-switch
1 set
to ON
=> on the MASTER Wi-Fi the dual-colored LED EDGE PHOT 1 flashing red will turn
green and a buzzer will signal that memorization of the photocell has been done correctly.
At the same time on MASTER Wi-Fi the dual-colored LED EDGE PHOT 2 will begin flashing
red for 1 minute (the time necessary to perform memorization
*
).
If there are no other photocells to be memorized let a minute pass or push the button PROG.
RX 4 times to complete the memorization procedure (the LED EDGE PHOT 2 shuts off) =>
all of the LEDs EDGE PHOT should be off during normal operation.
-
Assemble the cover
(7)
attaching it to the base
(8)
on the bottom part using the special
tooth, and then close the cover (Fig. 6).
-
Once the cover is closed, check that it is parallel to the base. Otherwise, open it again and
check that the circuit and the connection wires are correctly fitted in their seats.
-
Fasten the cover
(7)
to the base
(8)
with the 4 self-tapping screws TCCR2,9X9,5 supplied
(11)
(Fig. 6).
ATTACH THE YELLOW LABEL WITH THE IDENTITY NUMBER TO THE COVER (supplied in
the MASTER Wi-Fi packaging).
* TO MEMORIZE OTHER VERTIGO Wi-Fi PHOTOCELLS:
-
Push the button
S3 PROG
on the VERTIGO Wi-Fi receiver with micro-switch
2 set to ON
=> on the MASTER Wi-Fi the dual-colored LED EDGE PHOT 2 flashing red will turn green
and a buzzer will signal that memorization of the photocell has been done correctly.
NOTE:
at the end of the memorization procedure and after having enabled the micro-
switches for the safety devices memorized on the MASTER Wi-Fi, run a scan on the dual-
colored LED EDGE PHOT pushing the button PROG. RX 6 times.
-
If, after closing the cover with the RX bellow, the led should remain on, this means that
the photocells are already correctly aligned. The led will remain on for 5 minutes, in order
to carry out functional checks.
-
If the red led remains switched off after closing the protective cover, for no more than 5
minutes, check for correct alignment (as in the illustration)and for any deformation of the
bellows; after the checks, the red led should light on.
SYSTEM CHECK
After finishing the mounting procedure, check the correct working order between the
VERTIGO Wi-Fi photocells and the MASTER Wi-Fi by doing the following:
-
Check that the red led on the infrared receiver RX VERTIGO Wi-Fi is on. Otherwise, press
the pushbutton S3 PROG to light on the red led for 5 minutes.
-
Place an object between them and check that the red LED turns off and that at the same
time on the MASTER Wi-Fi the corresponding LED EDGE PHOT is on and green while the
object is present.
-
The LED DL2 of the MASTER Wi-Fi should also turn off indicating the correct exchange of
dedicated contact with the EDGE entry on the motor control panel.
-
Repeat the process on the other VERTIGO Wi-Fi photocells installed.
-
Then perform a system check of all the photocells installed by activating the movement of
the automation and checking that when an object is present the automation stops/reverses
when closing, or stops/continues to open when opening.
CLOSING THE VERTIGO CONTAINERS
Lastly, place the screw cover caps
(6) (12)
both on the TX and on the RX of the VERTIGO
Wi-Fi (Fig. 2-6), by inserting them into the 4 holes so that they are perfectly attached.
ANTENNA
The radio antenna is already connected to all of the VERTIGO Wi-Fi receivers.
DO NOT TOUCH IT !!!
WARNING
(notice about replacing the batteries, indicated by MASTER Wi-Fi)
The WARNING tells the user of the immediate need to replace the batteries.
When battery power reaches 2,3V, the photocell receiver signals the MASTER Wi-Fi via radio
of the low battery status and activates the BUZZER of the MASTER Wi-Fi with a sound every
3 seconds for 1 minute.
The warning is renewed for 1 minute if a command is given to the door.
The dual-colored LED on the MASTER Wi-Fi of the photocell with the low batteries emits a
constant red light.
The system is still operational during these signals, but it is advantageous to replace the
batteries as soon as possible in order to avoid a full stop of the door operation which
happens when the batteries reach 2,0 V.
ATTENTION:
The SPARK Wi-Fi flashing light changes flash modes during the warning status;
flashing 2 times in quick succession followed by a 2 second pause.
ALARM STATUS
(indicated by MASTER WI-Fi)
The alarm activates when the batteries have been exhausted (2,0 V) or when a photocell
is not working.
On MASTER Wi-Fi LEDs DL2 and DL3 turn off, stopping the automation due to the fact that
one of the photocells installed is not working properly.
On MASTER Wi-Fi (fw 01_04_13) the LED of VERTIGO with the low or exhausted battery,
lights flashing red and the BUZZER emits a sound every 3 seconds for 1 minute to alert the
user that the batteries or the photocell need attention.
The alarm is renewed for 1 minute if a command is given to the door.
IN ORDER TO REMOVE THE SINGLE PHOTOCELL FROM THE Wi-Fi SYSTEM READ THE
MASTER Wi-Fi CARD MANUAL.
CHANGING THE BATTERIES
The duration of the batteries used for VERTIGO Wi-Fi photocells is about 3 years.
-
Identify which photocell has the exhausted batteries by looking at the LED EDGE-PHOT on
the MASTER Wi-Fi card.
-
Identify through the use of the number of the pair of photocells with the exhausted batteries
on the side of the dual-colored LED that:
- alternately flash red to green (if the alarm is on)
- Master Wi-Fi fw 01_04_13 lights flashing red (if the warning is on)
- has a constant green light (if the VERTIGO Wi-Fi transmitter batteries are
exhausted)
-
Locate the adhesive strip with the corresponding identity number of the photocells on the
outside of the container.
-
Replace the batteries of both the transmitter and receiver checking that the polarity is
correct.
-
Push the button S3 PROG of the photocell receiver to reactivate the MASTER Wi-Fi. The
buzzer on the edge of the MASTER Wi-Fi card turns off and the LED DL2- DL3 (if the
alarm is on) turn on and the dual-colored LED of the photocell with the replaced batteries
turns off.
The automation is now ready to begin safe operation once more.
ATTENTION: Please remember that batteries must be disposed of properly according
to current standards. In case of disposal of the photocells please remember to
remove and dispose of the batteries properly.
REMOVAL PROCEDURE FOR A SINGLE VERTIGO Wi-Fi FOR
BREAKDOWN OR SUBSTITUTION
In order to remove a single memorized VERTIGO on the MASTER Wi-Fi, use the following
procedure:
-
Push the button PROG. RX one or more times to select the dual-color LED EDGE PHOT
which begins flashing green, corresponding to VERTIGO to be eliminated.
-
After selecting the photocell, push and hold the button PROG. RX for 10 seconds.
-
After 10 seconds the dual-color LED EDGE PHOT flashes alternately red and green 6 times,
indicating successful removal.
WARNING:
Turn the micro-switch for the eliminated VERTIGO on “OFF” position and press
the PROG. RX pushbutton 6 times to carry out the scanning of the two-coloured leds.
IMPORTANT:
Remove the batteries from the eliminated safety device.
12/24V ac/dc
PROG RX
DL2
DUAL-COLORED LED EDGE PHOT
INFRARED SIGNAL RECEIVER - RX
Summary of Contents for ACG8042
Page 30: ...30 NOTES ...
Page 31: ...31 NOTES ...
Page 32: ...32 ...
Page 33: ...33 ...
Page 34: ...34 ...