ANEMOMETER:

 universal device for measuring wind speed. Easy to install and control, this is an excellent and elegant system for protecting your  awning; when the wind exceeds a set 

threshold it closes/rewinds your awning. This sensor consists of a fixed part (casing containing electronics on a special support) and a mobile part (rotating axis with 3 blades). The device 
should be installed in a place where the wind can be measured and not therefore behind walls or other protections. To fit the sensor, secure the retention plate using the 4 screws and wall 
anchors, and then fasten the anemometer by sliding it in the special guide. Finally. Connect up to the MINI TS or MINI TS 2nd edition unit.
The sensor is supplied with two-pole shielded cable: one 

white pole or braiding

 for connecting up the positive power voltage lead (

Terminal 7

 of the 

MINI TS 

unit or

 terminal 1 

of the

 

MINI TS 2nd edition 

unit or

 terminal 2 

of the

 MINI TS SV 

unit or

 terminal 5 

of the

 MINI TS SV 2nd edition 

unit) and a 

green pole or core

 for the output signal to be connected to 

terminal 6

 of the 

MINI TS 

unit or

 terminal 4 

of the

 MINI TS 2nd edition 

unit or 

terminal 3 

of the 

MINI TS SOLO VENTO 

unit or

 terminal 4 

of the

 MINI TS SV 2nd edition 

unit.     

When wiring up, keep to the diagram shown in the MINI TS or MINI TS 2nd edition or MINI TS SV or MINI TS SV 2nd edition unit instructions.    

ANEMOMETER WITH CREPUSCULAR SENSOR:

 same as above as regards reading of wind force, this unit also features a sensor for reading ambient light. 

The light intensity read by the sensor is translated into an analogue signal in current (4…20mA) proportionately to the read value (4mA = dark, 20mA = bright light). The device is supplied 
with a 4-pole cable: two for the light sensor and two for the wind sensor, according to the following colours:       
WIND SENSOR: 

 white = power supply positive pole, to be connected to 

terminal 7

 of the 

MINI TS

 unit or to 

terminal 1 

of the

 MINI TS 2nd edition 

unit or to

 terminal 5 

of the

 MINI 

TS SV 2nd edition 

unit.                               

 

 green = output signal, to be connected to 

terminal 6

 of the 

MINI TS

 unit or to 

terminal 4

 of the

 MINI TS 2nd edition 

unit or to

 terminal 4 

of the

 MINI TS SV 2nd 

edition 

unit.         

LIGHT SENSOR: 

 red or blue = power supply positive pole to be connected to 

terminal 8

 of the 

MINI TS

 unit or to 

terminal 1 

of the

 MINI TS 2nd edition 

unit.            

 

 yellow = output signal to be connected to 

terminal 9

 of the 

MINI TS

 unit or to 

terminal 7 

of the

 MINI TS 2nd edition 

unit. 

When wiring up, keep to the diagram shown in the MINI TS or MINI TS 2nd or MINI TS SV 2nd edition edition unit instructions.    

CREPUSCULAR SENSOR:

 

 sensor for reading ambient light. To be connected to the MINI TS or MINI TS 2nd edition unit. It opens the awning in the presence of sunlight. This device 

must not be shaded by lean-tos, balconies, etc., otherwise it is unable to read the intensity of the sunlight. Cable connection (Also see connection diagrams):          
Terminal 1 = + Power supply, connect to 

terminal 8

 of the 

MINI TS

 unit or to 

terminal 1 

of the

 MINI TS 2nd edition 

unit            

Terminal 2 =    Signal output, connect to 

terminal 9

 of the 

MINI TS

 unit or to 

terminal 7 

of the

 MINI TS 2nd edition 

unit

BE CAREFUL NOT TO REVERSE THE POLES !! 

When wiring up, keep to the diagram shown in the MINI TS or MINI TS 2nd edition unit instructions.      

RAIN SENSOR:

 universal device for reading rain intensity and signalling this to the MINI TS or MINI TS 2nd edition unit. 

The  output  signal  is  of  the  ON/OFF  type  in  current  (ON  =  rain  =  20mA,  OFF  =  no  rain  =  10mA)  The  switchover  lever  can  be  set  by  the  skilled  personnel  (installer)    by  means  of  an 
adjustment trimmer accessible by opening the plastic box. When making the setting consider: 
a) With the trimmer set at maximum, output signal transition occurs with heavy rain. 
b)  With the trimmer set at minimum, the output transition signal occurs with lighter rain. 
The sensor also features an internal heater that can be powered separately and which is useful during the winter to prevent the formation of ice on the sensitive part of the device, thus 
jeopardising correct operation. Connections:               
Terminals 1 and 2  =  Connect to external power supply 12-24 V dc/ac  -  2W                   
Terminal 3 

=  Power supply, connect to 

terminal 8

 of the 

MINI TS

 unit or to 

terminal 1 

of the

 MINI TS 2nd edition 

unit

Terminal 4 

=  Signal output, connect to 

terminal 10

 of the 

MINI TS

 unit or to 

terminal 10 

of the

 MINI TS 2nd edition 

unit 

BE CAREFUL NOT TO REVERSE THE POLES !! 

When wiring up, keep to the diagram shown in the MINI TS or MINI TS 2nd edition unit instructions.    

ANEMOMETER   

ANEMOMETER WITH CREPUSCULAR SENSOR      

CREPUSCULAR  

RAIN SENSOR 

Anemometer or 

Anemometer with 

crepuscular sensor          

Wall retention plate 

Connection cable 

Rain sensor 

Crepuscular sensor

Do not change this

trimmer setting

To 

MINI TS

 terminal 

9

 V-

or to 

MINI TS 2nd edition

 terminal 

7

 V- 

To 

MINI TS

 terminal 

8

 V+

or to 

MINI TS 2nd edition

 terminal 

V+

Rain sensor thre-shold  
adjustment trimmer 

To external power supply  12/24 

Vac/dc 

To 

MINI TS

 terminal 

or to 

MINI TS 2nd edition

 

terminal 

1

To 

MINI TS

 terminal 

10 

or to 

MINI TS 2nd edition

 terminal 

10

Crepuscular control unit 

Rain Sensor control unit

 WIRING DIAGRAMS

code ACG2275   
code ACG2276         
code ACG2270   
code ACG2271 

&RG&9$5HY

  25014 CASTENEDOLO (BS) - ITALY

Via Matteotti, 162

Tel. +39.030.2135811

Fax +39.030.21358279

www.ribind.it - [email protected]

Summary of Contents for ACG2275

Page 1: ...ruzioni del quadro elettronico MINI TS o MINI TS 2nd edition o MINI TS SV 2nd edition CREPUSCOLARE sensore per la rilevazione della luce ambiente Da collegarsi al quadro elettronico MINI TS o MINI TS 2nd edition Provvede ad attivare l apertura della tenda in presenza di sole Collegamenti dei cavi Vedere anche gli schemi di collegamento Morsetto 1 Alimentazione collegare al morsetto 8 del quadro el...

Page 2: ...eur pour la détection de la lumière ambiante à raccorder à la centrale MINI TS ou MINI TS 2nd edition Il active le déploiement du store en présence de soleil Ce dispositif également ne doit pas être masqué par des toitures balcons etc si c est le cas il ne pourra pas détecter l intensité de la lumière solaire Branchements des câbles Voir également les schémas de raccordement Borne 1 Alimentation r...

Page 3: ...on edition unit instructions CREPUSCULAR SENSOR sensor for reading ambient light To be connected to the MINI TS or MINI TS 2nd edition unit It opens the awning in the presence of sunlight This device must not be shaded by lean tos balconies etc otherwise it is unable to read the intensity of the sunlight Cable connection Also see connection diagrams Terminal 1 Power supply connect to terminal 8 of...

Page 4: ... DE LUZ sensor para la detección de la luz ambiente Ha de conectarse a la centralita MINI TS o MINI TS 2nd edition y activa la apertura del toldo en presencia de sol También este dispositivo no tiene que ser obscurecido por cobertizos balcones etc si fuera así no detectaría la intensidad de la luz solar Conexiones de los cables Véase también esquemas de conexión Borne 1 Alimentación conectar al bo...

Reviews: