background image

KING EVO

ITALIANO pag. 05 / FRANÇAIS pag. 19 / ENGLISH page 33 / DEUTSCH pag. 47 / ESPAÑOL pag. 61

Operatore
Operateur

Operator

Torantrieb

Operador

Alimentazione

Alimentation

Power Supply

Stromspannung

Alimentacion

Peso max anta

Poids maxi battant

Max leaf weight
Max Torgewicht

Peso máximo anta

Forza max di spinta

Force maxi de poussée

Thrust force

Max. Schubkraft

Fuerza max de empuje

Codice

Code
Code
Kode

Codigo

Codice KIT

Code KIT
KIT Code
KIT Kode

Codigo KIT

KING EVO

230V 50/60Hz

400 kg / 880 lbs

2570/2540 N

AA14050

AD14050B

120V 60Hz

2027 N

AA14052

KING EVO L

230V 50/60Hz

500 kg / 1100 lbs

2570/2540 N

AA14070

120V 60Hz

2027 N

AA14072

KING EVO ICE

230V 50/60Hz

400 kg / 880 lbs

2570/2540 N

AA14060

KING EVO L ICE

500 kg / 1100 lbs

AA14075

Il corretto funzionamento dell’operatore è garantito solo se viene gestito da un quadro di comando RIB

Le bon fonctionnement de l’opérateur n’est garanti que s’il est géré par un panneau de contrôle RIB

The correct operation of the operator is guaranteed only if it is managed by a RIB control panel

Die korrekte Bedienung des Bedieners ist nur gewährleistet, wenn er von einem RIB-Bedienpanel verwaltet wird

El funcionamiento correcto del operador solo está garantizado si está gestionado por un panel de control RIB

con / avec / with / mit 

B2-CRX

Vedere pagina 18
Voir page 32
See page 46
Siehe Seite 60
Ver página 74

Disegni tecnici per progetti
Dessins techniques pour les projets
Technical drawings for projects
Technische Zeichnungen für Projekte
Dibujos técnicos para proyectos.

Summary of Contents for AA14050

Page 1: ...0Hz 400 kg 880 lbs 2570 2540 N AA14060 KING EVO L ICE 500 kg 1100 lbs AA14075 Il corretto funzionamento dell operatore garantito solo se viene gestito da un quadro di comando RIB Le bon fonctionnement...

Page 2: ...ovocati dalla mancata osservanza nell installazione delle norme di sicurezza e delle leggi attualmente in vigore ATTENTION POUR LA SECURITE DES PERSONNES IL EST IMPORTANT DE SUIVRE TOUTES LES INSTRUCT...

Page 3: ...s caused by the non observance during the installation of the safety standards and of the laws in force at present ACHTUNG F R DIE SICHERHEIT DER PERSONEN IST ES WICHTIG DASS ALLE ANWEISUNGEN GENAU AU...

Page 4: ...dell acquisto di una nuova apparecchiatura di tipo equivalente Presso i distributori di prodotti elettronici con superficie di vendita di almeno 400 m2 inoltre possibile consegnare gratuitamente senz...

Page 5: ...nterviene durante la chiusura opzionale la corsa massima di traino si riduce di 40 mm KING EVO ICE e KING EVO ICE L 30 55 C 1 Operatore KING EVO 2 Antenna radio 3 Lampeggiatore 4 Selettore a chiave 5...

Page 6: ...Se la colonna in ferro le si pu saldare direttamente l attacco Se la colonna in cemento si utilizza la piastra come in Fig 5 e la si fissa con quattro viti ad espansione di 8 mm Altro intervento poss...

Page 7: ...KING EVOcon 1 fermo meccanico A max max C D T max sec COL 0 20 110 120 815 24 S1 X 20 40 26 40 60 27 60 100 105 29 100 120 30 S1 Y 120 140 100 31 KING EVOcon 2 fermi meccanici A max max C D T max sec...

Page 8: ...O Lcon 2 fermi meccanici A max max B C D T max sec 0 100 115 170 160 905 33 100 140 110 200 35 140 180 105 250 38 110 D A C L 55 B KING EVOL MISURE DA RISPETTARE PER UNA CORRETTA INSTALLAZIONE Rispett...

Page 9: ...su siti commerciali ed industriali valori indicati nel punto 5 3 5 della norma EN 12453 SICUREZZE ELETTRICHE Realizzare l impianto in ottemperanza alle norme ed alle leggi vigenti Si consiglia l utili...

Page 10: ...LED R 2 2K 1 4W SERRATURA ELETTRICA CHIUDE APRE COMUNE CHIUDE APRE COMUNE ANTENNA 433 MHz SCHERMATURA CAVO D ANTENNA LAMPEGGIATORE 230Vac 40W FINECORSA APERTURA M1 FINECORSA CHIUSURA M1 COMUNE FINECO...

Page 11: ...mune dei contatti Positivo 24 Vdc STOP Contatto impulso di stop NC PHOT 1 Contatto fotocellule 1 NC PHOT 2 Contatto fotocellule 2 NC EDGE 1 Contatto costa 1 NC EDGE 2 Contatto costa 2 NC J15 COM A Com...

Page 12: ...a dopo l apertura pedonale prima di avere la chiusura automatica del cancello R AUX CONTATTO REL AUSILIARE NA Di fabbrica questo rel impostato come luce di cortesia max 700 W 3 A 230 Vac per funzionar...

Page 13: ...ne si pu ottenere solo a cancello fermo 1 Posizionare prima il DIP 1 su ON e poi il DIP 2 su ON 2 Il led DL12 lampeggia per 6 volte verde segnalando memoria satura 1000 codici presenti Successivamente...

Page 14: ...la liberazione del raggio delle fotocellule DIP 4 ON A cancello chiuso se un ostacolo davanti al raggio delle fotocellule e viene comandata l apertura il cancello apre durante l apertura le fotocellu...

Page 15: ...tura ambiente motore sia inferiore a 10 C Al raggiungimento dei 20 C il riscaldatore si spegne mantenendo le condizioni ambientali a temperatura costante CARATTERISTICHE TECNICHE PROBE Tensione di fun...

Page 16: ...bbinato Allarme da autotest fotocellule fallito 4 Toni ogni 5 s per 1 minuto Si rinnova dando un comando Spento Nessun led abbinato Allarme da Encoder 5 Toni ogni 5 s per 1 minuto Si rinnova dando un...

Page 17: ...25 m cod ACG8046 FOTOCELLULE NOVA WIRELESS portata 25 m durata batterie 3 anni cod ACG8047 COPPIA DI COLONNINE per NOVA cod ACG8039 SAIL SAIL arancio con scheda intermittente incorporata cod ACG7072 S...

Page 18: ...i APP8050 Scheda APP per gestire la centrale di comando tramite Bluetooth APP8054 Scheda APP per gestire la centrale di comando tramite Bluetooth APP8064 Modulo Wi Fi per Scheda APP per gestire la cen...

Page 19: ...ING EVO ICE L 30 55 C 1 Operateur KING EVO 2 Antenne radio 3 Signal electrique 4 Selecteur 5 Photocellules p protection externe CARACTERISTIQUES TECHNIQUES KING EVO KING EVO L Longueur maxi du battant...

Page 20: ...code BA10153 Si la colonne est en fer il est possible de sonder directement la fixation Si la colonne est en ciment proceder toujours avec une plaque comme indique Fig 5 et la fixer avec quatre Fisch...

Page 21: ...mouvement NON S1 Z Y X COL Attache poteau KING EVO KING EVOavec 1 arret mecanique A max max C D T max sec COL 0 20 110 120 815 24 S1 X 20 40 26 40 60 27 60 100 105 29 100 120 30 S1 Y 120 140 100 31 KI...

Page 22: ...te 55 et s assurer que le piston soit horizontal 10 KING EVO Lavec 2 arret mecaniques A max max B C D T max sec 0 100 115 170 160 905 33 100 140 110 200 35 140 180 105 250 38 110 D A C L 55 B KING EVO...

Page 23: ...s portes et portails usage industriel et commercial valeurs indiqu es au paragraphe 5 3 5 de la norme EN 12453 SECURITES ELECTRIQUES Adapter les installations des parties electriques aux normes et loi...

Page 24: ...RURE ELECTRIQUE FERMETURE OUVERTURE COMMUN FERMETURE OUVERTURE COMMUN ANTENNE 433 MHz ENVELOPPE ANTENNE FEU CLIGNOTANT 230Vac 40W FIN OUVERTURE M1 FIN FERMETURE M1 COMMUN FIN OUVERTURE M2 FIN FERMETUR...

Page 25: ...24 Vdc STOP Contact impulsion de stop NF PHOT 1 Contact photocellules 1 NF PHOT 2 Contact photocellules 2 NF EDGE 1 Contact barre palpeuse de s curit 1 NF EDGE 2 Contact barre palpeuse de s curit 2 NF...

Page 26: ...eut tre r gl entre 2 s minimum et 30 s maximum Ex Avec TCA demi course vous aurez une pause d une minute apr s l ouverture totale et de 15 s apr s l ouverture pietonne avant d avoir la fermeture autom...

Page 27: ...tationnaire 1 Positionner le DIP 1 sur ON et ensuite le DIP 2 sur ON 2 La LED DL12 clignote rouge pendant 10 s 3 Pendant ces 10 s enfonc et maintenir appuy le bouton PROG pendant 5 s La confirmation d...

Page 28: ...GE MANUEL DES MOTEURS Mettre le DIP 10 sur ON pour activer la facilitation au d blocage manuel Une fois la fermeture termin e une man uvre d inversion sera ex cut e avec un temps fixe de 0 2s pour fac...

Page 29: ...blocage du moteur cause du gel Ce dispositif s active automatiquement lorsque le portail est l arr t la position n a pas d importance il suffit qu il soit l arr t une temp rature ambiante moteur inf r...

Page 30: ...autotest photocellule 4 Tonalit s toutes les 5 s pendant 1 minute Renouvel e par l actionnement d une commande teint Aucune led associ e Blocage fonctionnel ex cut par smartphone teint teint Led DL12...

Page 31: ...S NOVA port e 25 m code ACG8046 PHOTOCELLULES NOVA WIRELESS port e 25 m dur e batteries 3 ann es code ACG8047 PAIRE DE POTEAUX pour NOVA code ACG8039 FIT SLIM EN12978 EN13849 2 PHOTOCELLULES MURALES c...

Page 32: ...g rer le tableau de contr le via Bluetooth 4 2 APP8054 Carte APP pour g rer le tableau de contr le via Bluetooth 4 2 APP8064 Module Wi Fi pour Carte APP pour g rer le tableau de contr le via un r seau...

Page 33: ...CAL DATA KING EVO KING EVO L Max leaf length m 4 5 Max leaf weight kg 400 500 Max travel mm 368 498 Average opening time s 20 25 26 33 Operating speed m s 0 0125 EEC Power supply 230V 50Hz Thrust forc...

Page 34: ...easures If there is an iron pillar you can weld the attachment directly If there is a cement pillar you can use the fixing plate as in Fig 5 which is fastened with 4 Fischer screws of 8 mm There is al...

Page 35: ...9 S1 Z Y X COL Column attachment KING EVO KING EVOwith 1 mechanical stopper A max max C D T max sec COL 0 20 110 120 815 24 S1 X 20 40 26 40 60 27 60 100 105 29 100 120 30 S1 Y 120 140 100 31 KING EV...

Page 36: ...FOR A CORRECT INSTALLATION 10 KING EVO Lwith 1 mechanical stopper A max max B C D T max sec 0 140 120 240 945 38 0 100 115 170 160 33 100 140 110 200 35 140 180 105 250 38 KING EVO Lwith 2 mechanical...

Page 37: ...ings and 390N for doors gates for commercial and industrial sites values indicated in 5 3 5 of the EN 12453 norm ELECTRICAL SAFETY DEVICES The installation must be installed according to the current r...

Page 38: ...4W ELECTRIC LOCK CLOSE OPEN COMMON CLOSE OPEN COMMON ANTENNA 433 MHz ANTENNA BRAIDING BLINKER 230Vac 40W LIMIT SWITCH OPEN M1 LIMIT SWITCH CLOSE M1 COMMON LIMIT SWITCH OPEN M2 LIMIT SWITCH CLOSE M2 C...

Page 39: ...J14 COM A Common contacts Positive 24 Vdc STOP STOP impulse contact NC PHOT 1 Photocells contact 1 NC PHOT 2 Photocells contact 2 NC EDGE 1 Edge 1 contact NC EDGE 2 Edge 2 contact NC J15 COM A Common...

Page 40: ...contact by TRANSMITTER by performing the memorization procedure described in point H LED WARNING DL1 PROG programming activated red DL2 M1 gate opening green DL3 M1 gate closing red DL4 M2 gate openi...

Page 41: ...can be done only when the gate is stationary 1 Set DIP 1 to ON and then DIP 3 to ON DL12 flashes green for 10 s 2 Press the transmitter button usually channel B within the allotted 10 s If the transmi...

Page 42: ...ovement is not allowed Normal operation can be restored only by repairing the photocell and pressing one of the controls EDGES SAFETY STRIPS COM A EDGE 1 COM A EDGE 2 If engaged when closing EDGE 1 re...

Page 43: ...n frequency 433 92 MHz Impedence 52 Sensitivity 1 V Feedback control PLL Memory storage codes 1000 All the inputs must be used as clean contacts because the power supply is generated internally safe v...

Page 44: ...ON OFF 500 ms DIP 2 ON DIP 1 ON pedestrian stroke programming OFF OFF Flashes ON OFF 500 ms Programming sequence stopped due to intervention of a safety device 10 s tone with 2 s pause OFF On steady E...

Page 45: ...or 2 leaf gates to latch closed gate to the ground code ACG5000 VERTIGO PHOTOCELLS SUBSTITUTING THE SAFETY STRIP VERTIGO 8 cod ACG8044 VERTIGO 10 cod ACG8045 FIT SLIM EN12978 EN13849 2 PHOTOCELLS for...

Page 46: ...ontrol panel using Bluetooth 4 2 transmission APP8060 Clock module for APP card to add access control features to the control panel APP8064 Wi Fi module for APP card to manage the control panel using...

Page 47: ...um 40 mm KING EVO ICE und KING EVO ICE L 30 55 C 1 E Torantrieb KING EVO 2 Antenne 3 Blinkleuchte 4 Schlusselschalter 5 Photozelle Toraussenseitig TECHNISCHE EIGENSCHAFTEN KING EVO KING EVO L Max Tor...

Page 48: ...n man die Verankerung direkt anschwei en Bei einem Tortr ger aus Zement bedient man sich einer Platte wie in Abb 5 die man mit 4 Fischer D bel 8 mm anschraubt Man kann die Verankerung auch in den Tr g...

Page 49: ...chanische sperrvorrichtung A max max C D T max sec COL 0 20 110 120 815 24 S1 X 20 40 26 40 60 27 60 100 105 29 100 120 30 S1 Y 120 140 100 31 KING EVOmit 2 Mechanische sperrvorrichtungen A max max C...

Page 50: ...EINE RICHTIGE INSTALLATION Die H he 55 muss gehaltet werden und stellen Sie sicher da der Betrieb horizontal ist KING EVO Lmit 2 Mechanische sperrvorrichtungen A max max B C D T max sec 0 100 115 170...

Page 51: ...f r Tore f r kommerzielle und industrielle Situationen Werte nach 5 3 5 vom EN 12453 Norm ELEKTRISCHE SICHERHEITEN Die Installation mu nach den aktuellen Gesetznormen installiert werden Es wird die Ve...

Page 52: ...N FFNEN GEMEINSAMER ANTENNE 433 MHz ANTENNE ZOPFFLECHTEN BLINKER 230Vac 40W ENSCHALTER FFNEN M1 ENSCHALTER SCHLIESSEN M1 GEMEINSAMER ERDUNGSKONTAKT GEMEINSAMER ERDUNGSKONTAKT GEMEINSAMER ERDUNGSKONTAK...

Page 53: ...uls Kontakt NS PHOT 1 Fotozellen Kontakt 1 NS PHOT 2 Fotozellen Kontakt 2 NS EDGE 1 Ripppen Kontakt 1 NS EDGE 2 Ripppen Kontakt 2 NS J15 COM A Gemeinsame erdungskontakte Positive 24 Vdc B I O Uhr Kont...

Page 54: ...e Pause von 15 s bevor Sie das Tor automatisch schlie en R AUX ZUSATZRELAISKONTAKT NO Standardm ig ist dieses Relais als Hilfslicht max 700 W 3 A 230 VAC eingestellt um bei jedem Befehl 3 Minuten zu a...

Page 55: ...e f r 10 s 3 Die Taste PROG 5 s lang gedr ckt halten Die Speicherl schung wird durch zwei gr ne Blinksignale der LED DL12 und 2 Signalt ne des Summers angezeigt 4 LED DL12 blinkt f r 10 s erneut rot u...

Page 56: ...TROSCHLOSS IM VERSCHLUSS ZU ENGAGIEREN DIP 11 ON um die Freigabe der elektrischen Verriegelung w hrend der Schlie ung zu aktivieren Nach vollst ndiger Schlie ung laufen die Motoren bei voller Spannung...

Page 57: ...zu 30 C dies um eine Blockierung des Motors zu verhindern Diese Vorrichtung aktiviert sich automatisch bei Stillstand des Tores ohne Einfluss auf die Position vorausgesetzt ist jedoch der Arrest dies...

Page 58: ...rteilt BLINKT F R 1 MINUTE Keine kombinierte LED Alarm selbsttest fehlgeschlagen 4 T ne alle 5 s f r 1 Minute Es wird verl ngert indem man einen Befehl erteilt Abgeschaltet Keine kombinierte LED Funkt...

Page 59: ...NOVA Reichweite 25 m Kode ACG8046 FOTOZELLEN NOVA WIRELESS Reichweite 25 m Batterienlebenslauf 3 Jahre Kode ACG8047 DOPPEL S ULEN f r NOVA Kode ACG8039 FIT SLIM EN12978 EN13849 2 WANDFOTOZELLEN Kode...

Page 60: ...teuerung mit Bluetooth 4 2 bertragung zu verwalten APP8060 Uhrenmodul f r APP Karte um Zugriff auf das Steuerungen hinzuzuf gen APP8064 WLAN Modul f r APP Karte Verwalten des Steuerung ber das lokale...

Page 61: ...l la carrera m xima de remolque se reduce de 40 mm KING EVO ICE y KING EVO ICE L 30 55 C 1 Operador KING EVO 2 Antena de radio 3 Intermitente 4 Interruptor de llave 5 Fotoc lulas esternas CARACTER STI...

Page 62: ...para el operador ENGANCHE COLUMNA PARA KING EVO L c d BA10153 Si la columna es de hierro se le puede soldar directamente el enganche Si la columna es de cemento se utiliza una plancha como en la Fig 5...

Page 63: ...on 1 final de carrera A max max C D T max sec COL 0 20 110 120 815 24 S1 X 20 40 26 40 60 27 60 100 105 29 100 120 30 S1 Y 120 140 100 31 KING EVOcon 2 final de carrera A max max C D T max sec COL 0 2...

Page 64: ...VO L MEDIDAS A RESPETAR PARA UNA INSTALACI N CORRECTA KING EVO Lcon 2 final de carrera A max max B C D T max sec 0 100 115 170 160 905 33 100 140 110 200 35 140 180 105 250 38 110 D A C L 55 B Respeta...

Page 65: ...e industriales valores indiacados en el punto 5 3 5 de la norma EN 12453 PROTECCIONES EL CTRICAS Realizar la instalaci n de acuerdo a con las normas y las leyes vigentes Seaconsejaelutilizodecentrales...

Page 66: ...2K 1 4W CERRADURA EL CTRICA CIERRE ABRE COM N CIERRE ABRE COM N ANTENA 433 MHz ARMADURA ANTENA INTERMITENTE 230Vac 40W FINAL APERTURA M1 FINAL CIERRE M1 COM N FINAL APERTURA M2 FINAL CIERRE M2 COM N C...

Page 67: ...p NC PHOT 1 Contacto de las fotoc lulas 1 NC PHOT 2 Contacto de las fotoc lulas 2 NC EDGE 1 Contacto banda de seguridad 1 NC EDGE 2 Contacto banda de seguridad 2 NC J15 COM A Com n de los contactos Po...

Page 68: ...na pausa de 1 minuto despu s de la apertura total y 15 s de pausa despu s de la apertura peatonal antes de tener el cierre autom tico de la puerta R AUX CONTACTO DE RELE AUXILIAR NA De f brica este re...

Page 69: ...esionado el pulsador PROG durante 5 s La cancelaci n de la memoria se se ala mediante dos intermitencias verde del led DL12 y dos tonos de BUZZER El led DL12 parpadea rojo durante 10 s y es posible in...

Page 70: ...abilitar el golpe de desenganche de la cerradura el ctrica en cierre Una vez que se produjo el cierre se gestionan por 1s los motores a plena tensi n para garantizar el enganche de la cerradura FUNCIO...

Page 71: ...ura ambiente motor bajo de 10 C relevada por el sensor de temperatura PROBE El funcionamiento del calentamiento del de los motor es se nota por el encenderse de los led DL2 DL3 para M1 y DL4 DL5 para...

Page 72: ...1 minuto Se renueva dando un mando Parpadea por 1 minuto Ning n led unido Alarma de autoprueba fotoc lulas fallida 4 Tonos cada 5 s por 1 minuto Se renueva dando un mando Apagado Ning n led unido Blo...

Page 73: ...i n en corriente alterna y portada de 20 metros Pueden ser aplicadas m s parejas de fotoc lulas cercanas gracias al circ ito de sincronizaci n A adir el TRANSMISOR TX SLIM SYNCRO c d ACG8029B para sin...

Page 74: ...a unidad de control a trav s de Bluetooth 4 2 APP8054 Tarjeta APP para administrar la unidad de control a trav s de Bluetooth 4 2 APP8064 M dulo wi fi para Tarjeta APP para administrar el panel de con...

Page 75: ...75...

Page 76: ...self test 2 Fotozellen FIT SLIM FIT SYNCRO mit Selbstkontrolle 2 fotoc lulas FIT SLIM FIT SYNCRO con autotest 2 fotocellule F97P F97I con autotest 2 photocellules F97P F97I avec autotest 2 photocells...

Page 77: ...UTOTEST est activ e et qu une seule photocellule est connect e un cavalier doit tre cr entre les bornes PHOT 1 et PHOT 2 Si le cavalier n est pas ex cut l autotest choue et le portail ne bouge pas WAR...

Page 78: ...5 Gruppo chiocciola BA10156 Gruppo traino BC04664 Probe CAL1523 SEMIG INF ANT KING EVO NOIR100 CCA1294 PIATTO X COLON REGOL KING PRIN CCA1470 FORCELLA POST KING EVO NOI100 CCM6303ZZ CUSCINETTO 6303ZZ...

Page 79: ...54 Gruppo sblocco BA10155 Gruppo chiocciola BA10156 Gruppo traino BC04664 Probe CAL1529 SEMIG INF ANT KIEVO L NOIR 100 CCA1470 FORCELLA POST KING EVO NOI100 CCM6303ZZ CUSCINETTO 6303ZZ JBL25 VCD CEL13...

Page 80: ...014 30 UE 2014 35 UE und 2014 53 UE Alle grundlegenden Anforderungen gem Anhang I der Richtlinie UE 2006 42 CE angewendet wurden Die bereinstimmung mit den genannten harmonisierten Normen sieht die Ve...

Reviews: