27
R-CRX ELECTRONIC CONTROL PANEL FUNCTIONS
R-CRX 230/50-60Hz cod. ABJ8040
• adjustable or infinite operating time
• pulsed or dead man operations in opens and/or closes.
• directional open - close commands
• stop command
• radio commands - step by step (open - stop - close) or automatic (open
- close)
• wired commands - step by step (open - stop - close) or automatic (open
- close)
• built-in radio receiver 433 MHz for SUN transmitters
• 1024 codes/remotes recordable
14
13
12
V
W
U
L
L
N
MOT
OR
14
13
12
V
W
U
L
L
N
MOT
OR
14
13
12
V
W
U
L
L
N
MOT
OR
RAD1
3
4
2
1
ON
1 2 3 4 5 6 7
12 13 14 15 16
17 18
-
+
RUN TIMER
DEADMAN OPEN
DEADMAN CLOSE
ADJ RUN TIMER
OPEN FUNCTION
IMPULSE OPEN
IMPULSE CLOSE
INFINITE RUN TIMER
GO FUNCTION
RADIO LEARN
BZ
11
10
9
8
TRASF
RELA
Y LIGHT
RELA
Y OPEN
RELA
Y CLOSE
FUSE
STOP COM OPEN CLOSEPHOTO
24Vdc
+
-
PE
L
N
230Vac
N
L
L
N
L
MOTOR
LIGHT
POWER ON
PHOTO
STOP
P1
T 6,3A
LED
U W V
GND ANT
NC
NO
C
S
AD-
A*A+
S
AD-
A*A+
7 6 0 5 4 R
POWER
CLOSE
LSC
OPEN
LSO
COM
JOLLY ONE
JOLLY BIG
JOLLY 20
JOLLY 22
JOLLY 22S
JOLLY 24
JOLLY ONE FIN MEC
JOLLY BIG FIN MEC
G
B
Summary of Contents for AA00101
Page 42: ...42 NOTES ...
Page 43: ...43 D NOTES ...