Modbus Registers 

 

Register 

Data 

Address 

(Decimal) 

Access 

Size 

 

Function 

Range 

/Command And 
Default value in 

HEX (Decimal) 

Specification 

Description 

40001 

Read / 

   Write 

16 

bit  

Write Parameters to 

EEPROM 

FF (255) 

 

To save parameters in Drive 

(EEPROM) send Hex value XXFF 

to Address 0. 

Where XX  is 

slave ID

 ranging 

from 1 to F7(1 - 247) 

For example: 

If slave id is 7  then write 07FF. 

Modbus Slave 

Address 

Range:1-F7  

(1-247) 

 

    Default: 1 (1) 

 

Slave ID can be changed using 

Modbus tool

 

 

Reset default 

parameters 

0008(8) 

 

Writing 0800 in address 0 will load 

default values in drive. 

40003 

Read / 

Write

 

16 
bit 

 

Modes (Default value: 0)

 

Analog Open Loop 

Mode 

(Mode 0) 

       0001(1) 

 

 

Mode byte:00 

Control byte:01 

 

Enable motor 

For analog mode, connect external 

potentiometer. 

       0000(0) 

Mode byte:00 

 Control byte:00 

Disable motor 

       0003(3) 

Mode byte:00 

    Control byte:03 

Brake 

Digital Closed Loop 

Mode                     

(Mode 1) 

0101(257) 

Mode byte:01 

   Control byte:01 

Enable motor in CW 

0100(256) 

Mode byte:01 

Control byte:00 

Disable motor 

0109(265) 

Mode byte:01 

Control byte:09 

Enable Motor in CCW 

0103(259) 

Mode byte:01 

Control byte:03 

Brake 

Digital Open loop 

Mode 

(Mode 2)

 

0201(513) 

Mode byte:02 

Control byte:01 

Enable motor in CW 

0200(512) 

Mode byte:02 

Control byte:00 

Disable motor 

0209(521) 

Mode byte:02 

Control byte:09 

Enable Motor in CCW 

0203(515) 

Mode byte:02 

Control byte:03 

Brake 

Analog Closed  

Loop Mode 

(Mode 3)

 

0301(769) 

Mode byte:03 

    Control byte:01 

Enable Motor 

0300(768) 

Mode byte:03 

    Control byte:00 

Disable Motor 

Summary of Contents for RMCS - 3001

Page 1: ...https www robokits co in Rhino Industrial 250W Brushless DC Motor Drive with RTU Modbus Model No RMCS 3001 Operating Manual v1 0 https www robokits co in...

Page 2: ...n description 4 Modbus Registers 5 Modbus Register Mapping 7 Control Modes 9 Hardware Connection 9 Mode 0 Analog Open Loop Mode 11 Mode 1 Digital Closed Loop Mode 11 Mode 2 Digital Open Loop Mode 11 M...

Page 3: ...on torque and control at higher speeds There is an LED indication for power and error states in this drive It is possible to run the motor in four different modes It has short circuit protection for t...

Page 4: ...Amps Peak 5 Amps per phase Pin description of the drive is as per below image Pins 1 6 are used for drive and RS485 Configuration Pin No Description 1 RS485 D 2 RS485 D 3 BRK 5V 4 DIR 5V 5 ENA 5V 6 GN...

Page 5: ...log Open Loop Mode Mode 0 0001 1 Mode byte 00 Control byte 01 Enable motor For analog mode connect external potentiometer 0000 0 Mode byte 00 Control byte 00 Disable motor 0003 3 Mode byte 00 Control...

Page 6: ...yte 01 Enable Minimum Speed Control Mode Set PWM speed in address 4 40005 4 Read Write 16 bit PWM Range 0000 12C0 0 4800 Default 0 0 Set PWM for digital open loop mode and analog minimum speed control...

Page 7: ...d default value in drive Control and Mode Register Address 0x02 40003 Default value 0x0000 MODE 15 8 CRTL 7 0 0 0 0 0 rw rw rw rw 0 0 0 0 DIR 0 BRK EN Bits 15 8 MODE 15 8 Mode byte Default 0x00 Bits 1...

Page 8: ...alue Set PWM for open loop mode Frequency Register FRQ Address 0x06 40007 Default value 0x0000 FRQ 15 0 rw Bits 15 0 FRQ 15 0 Frequency Default 0x0000 Maximum value 0x0190 Minimum value 0x0000 There i...

Page 9: ...es Motor can be run in 5 different modes o Mode 0 Analog Open Loop Mode o Mode 1 Digital Closed Loop Mode o Mode 2 Digital Open Loop Mode o Mode 3 Analog Closed Loop Mode o Mode 4 Analog Closed Loop M...

Page 10: ...10 P a g e https www robokits co in...

Page 11: ...and stable operation are critical for the satisfactory operation of the manufacturing or industrial process They are commonly used as Linear motors Servomotors Actuators for industrial robots Extruder...

Page 12: ...PWM register c If motor is not running in analog mode check external potentiometer connections and check enable connection as it must be connected with 5V d If timeout error check hardware connection...

Page 13: ...l may be adapted or reproduced in any material or electronic form without the prior written consent of the copyright holder This product and its documentation are supplied on an as is basis and no war...

Reviews: