RHEONIK Coriolis Flowmeter
Operation Manual RHE 07, 08, 11
Page
14
To modify numbers, press + or - buttons to increment or decrement the displayed num-
bers.
Use
Next
on the right to enter the next menu point. Following the
Next
–function, you will
be guided back into the initial measurement data display.
MASS FLOW TRANSMITTER
+ - Next
20mA= 130.0 g/min
decrement
number
increment
number
step to
next Menu
example
For a complete overview of the menu, please have a look at the menu flow chart in ap-
pendix.
2.1.3. Basic functions
This section gives a short description of all functions needed to setup all inputs and out-
puts according to individual requirements.
2.1.3.1. Zero calibration
Zero calibration should be carried out when:
the meter has been newly installed.
drastic piping or fluid changes have occurred.
meter operating temperature has changed considerably.