Replacing a Burner
The only tools necessary for this will be a ratchet with a ½ in.
socket and a #2 Phillips head screwdriver. Please consult the Use
and Care manual before performing any changes and be sure to
follow any safety messages in the manuals and on the appliance.
Always ensure the customer has read and obey all safety
messages.
1. Remove the hose from the gas valve and from the bottom of
the blower.
2. Disconnect the leads to the igniter and to the flame rod sensor,
as well as the ground.
3. Undo the two harnesses from the blower
4. Disconnect the two leads connected to the low gas pressure
switch and remove the cable harness from the top of the gas
valve using the Phillips head screwdriver.
5. Using the ratchet, remove the 5 bolts attaching the burner
assembly to the top of the water heater.
6. Once the bolds are removed, remove the entire burner
assembly.
7. You will now have to remove the blower from the burner by
using the Phillips head screwdriver to remove the four screws
8. Remove the old burner and the gasket
Summary of Contents for TRITON
Page 8: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis Wiring and Schematic Diagram 8 ...
Page 9: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis Connection Diagram 9 ...
Page 14: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis User Interface 14 ...
Page 15: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis User Interface 15 ...
Page 16: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis User Interface 16 ...
Page 17: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis User Interface 17 ...
Page 20: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis Sequence of Events 20 ...
Page 21: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis Sequence of Events 21 ...
Page 46: ...4 6 Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis Notes ...
Page 57: ...BACnet Configurations Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis 5 7 ...