![Rheem RHPD Series Installation Instructions Manual Download Page 5](http://html1.mh-extra.com/html/rheem/rhpd-series/rhpd-series_installation-instructions-manual_1451494005.webp)
55
Prior to March 1999, R-410A refrigerant cylinders had a dip
tube. These cylinders should be kept upright for equipment
charging. Post March 1999 cylinders do not have a dip
tube and should be inverted to ensure liquid charging of the
equipment.
• Do not install a suction line filter drier in the liquid line.
• A liquid line filter drier is standard on every unit.
• Desiccant (drying agent) must be compatible for POE oils
and R-410A.
3. Thermostatic Expansion Valve (TXV)
The Bi-Flow TXV is specifically designed to operate with
R-410A heat pumps.
Replacement of the TXV should only
be made with the factory specified bi-flow R-410A valve.
Do not use an R-22 TXV.
4. Tools Required For Installing & Servicing R-410A Models
Manifold Sets:
-Up to 800 PSIG High side
-Up to 250 PSIG Low Side
-550 PSIG Low Side Retard
Manifold Hoses:
-Service Pressure Rating of 800 PSIG
Recovery Cylinders:
-400 PSIG Pressure Rating
-Dept. of Transportation 4BA400 or BW400
!
R-410A systems operate at higher pressures than R-22 sys-
tems. Do not use R-22 service equipment or components on
R-410A equipment.
CAUTION
Summary of Contents for RHPD Series
Page 42: ...42 Zy...
Page 43: ...43...
Page 44: ...44...
Page 45: ...45 FIGURE 12 FIGURE 13...
Page 46: ...46 FIGURE 14 FIGURE 15 FIGURE 16...
Page 70: ...70 T2 T3 T1 COMP AUX 4 5 6 2 1 3 W FIGURE 22...
Page 76: ...76 PR T2 T3 T1 COMP AUX 4 5 6 2 1 3 FIGURE 28...
Page 78: ...78 PR T2 T3 T1 COMP VFD AUX 4 5 6 2 1 3 FIGURE 30...
Page 81: ...81 FIGURE 33...
Page 83: ...83...