18
Item
Range
Default
Value
Access
Level
Description
Pump Off Time 3 12:00A–11:59P
Installer Select OFF time for Pump Period #3 to stop.
Pump Speed 3
1–4 if 4-Speed
Enabled
0%–100% if Variable
Enabled
Installer
On 4-speed pumps, this denotes the selected
pump output (which connects to the pump for
the selected speed) for this pump period. On
variable-speed pumps, this denotes the PWM
signal to be provided to the pump for pump
operation.
Return Valve 3
Pool/Spa
Pool
Installer
Select the position of a 3-way valve located
between the heater and the Pool/Spa for this
scheduled pump period.
Suction Valve 3
Pool/Spa
Pool
Installer
Select the position of the 3-way valve located
between the Pool/Spa and the Pump for this
scheduled pump period.
Pump On Time 4 12:00A–11:59P
Installer Select ON time for Pump Period #4 to take
effect.
Pump Off Time 4 12:00A–11:59P
Installer Select OFF time for Pump Period #4 to stop.
Pump Speed 4
1–4 if 4-Speed
Enabled
0%–100% if Variable
Enabled
Installer
On 4-speed pumps, this denotes the selected
pump output (which connects to the pump for
the selected speed) for this pump period. On
variable-speed pumps, this denotes the PWM
signal to be provided to the pump for pump
operation.
Return Valve 4
Pool/Spa
Pool
Installer
Select the position of a 3-way valve located
between the heater and the Pool/Spa for this
scheduled pump period.
Suction Valve 4
Pool/Spa
Pool
Installer
Select the position of the 3-way valve located
between the Pool/Spa and the Pump for this
scheduled pump period.
Faults Last
Installer/
Service
Fault history starting with the most recent
and going back to 10 last faults. Using the
UP/DOWN buttons scrolls through the fault
history. If there are no faults present, the
display will read “All Faults Clear”.
Clear
Faults
Installer/
Service
Holding down the UP and DOWN buttons for
3+ seconds clears the recorded fault history
and “Faults Cleared” appears on the display.
Run Hours
XXXX
Cycles
XXXX
Installer/
Service
Displays the number of run hours that the
compressor has been running as well as the
number of cycles that the unit has operated.
(Continued on next page)
Summary of Contents for Raypak 2450
Page 43: ...43 Figure 15 Piping for Heat Pump Pool Heater and Gas Pool Heater...
Page 52: ...52 NOTES...
Page 53: ...53 NOTES...