Rheem RANL-JEZ Brochure Download Page 20

Before proceeding with installation, refer
to installation instructions packaged
with each model, as well as complying
with all Federal, State, Provincial, and
Local codes, regulations, and practices.

RHEEM
AIR CONDITIONING
DIVISION

5600 Old Greenwood Road, Fort Smith, Arkansas 72908

“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”

PRINTED IN U.S.A.

3-07 DC

FORM NO. A11-187  REV.  2

Supersedes Form No. A11-187 Rev. 1

GENERAL TERMS OF LIMITED WARRANTY

Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable
period stated, in accordance with the terms of the limited
warranty.

For Complete Details of the Limited Warranty, Including Applicable Terms
and Conditions, See Your Local Installer or Contact the Manufacturer for
a Copy.

Compressor ..............................................Ten (10) Years

*Any Other Part ..........................................Five (5) Years

*This five year limited warranty is applicable only to single-phase products

installed in residential applications on or after January 1, 2001.

RAPL- JEZ/RANL- JEZ Conditional Replacement
Warranty:

Rheem will provide a replacement model (if an

exact replacement is not available, an equivalent product will
be provided) to the original purchaser if the compressor fails
within 5 years (providing the unit is installed with a new
Rheem Air Handler OR Rheem Indoor Coil with a Rheem
Gas Furnace, and is properly matched as specified by
Rheem and/or listed in the Air Conditioning Institute (ARI)
published rating, and if additional conditions are satisfied.
See product warranty card for additional information.

BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE
FROM YOUR RETAILER.

Summary of Contents for RANL-JEZ

Page 1: ...ditional unit replacement warranty Compressor sound blanket is standard to provide quiet operation Attractive louvered wrap around jacket protects the coil from yard hazards and weather extremes Top g...

Page 2: ...hermetically sealed and incorporates internal high temperature motor overload protection and durable insulation on the motor windings It is externally mounted on rubber grommets to reduce vibration an...

Page 3: ...ient Control Cycles outdoor fan to maintain adequate condensing pressures assuring liquid refrigerant flow to the coil Allows indoor cooling with outdoor temperatures down to 0 F 17 8 C Model No RXAD...

Page 4: ...0 1 9 19 600 5 7 14 050 4 1 5 550 1 6 13 40 15 50 74 13 05 RCFL A 2417A RGPR 05 BMK 19 500 5 7 14 000 4 1 5 500 1 6 13 10 15 00 15 00 74 RCFL A 2417A RGPR 07 AMK 19 600 5 7 14 050 4 1 5 550 1 6 13 30...

Page 5: ...6 000 4 7 6 800 2 0 12 65 15 00 72 12 10 RCHL 24A2 RGFD 06 MCK 22 600 6 6 15 800 4 6 6 800 2 0 12 20 14 50 14 00 72 RCHL 24A2 RGFD 07 MCK 22 600 6 6 15 850 4 6 6 750 2 0 12 35 14 50 72 RCHL 24A2 RGGD...

Page 6: ...2 10 RCFL A 3617A RGLR 07 AMK 35 200 10 3 25 450 7 5 9 750 2 9 12 65 14 50 14 00 73 RCFL A 3617A RGPR 07 AMK 35 000 10 3 25 350 7 4 9 650 2 8 12 55 14 50 73 RCFL A 3617A RXMD C04 35 000 10 3 25 300 7...

Page 7: ...7 2 9 350 2 7 12 05 14 00 73 12 80 RCHL 36A2 RGFD 10 ZCM 34 200 10 0 24 500 7 2 9 700 2 8 11 95 14 00 14 50 73 RCHL 36A2 RGFD 12 ZCM 34 200 10 0 24 600 7 2 9 600 2 8 12 05 14 00 73 RCHL 36A2 RGGD 09...

Page 8: ...48A1 RGPR 07 BRQ 40 000 11 7 28 150 8 2 11 850 3 5 12 05 14 00 13 00 76 RCHL 48A1 RGPR 12 ARM 40 000 11 7 27 950 8 2 12 050 3 5 11 80 14 00 76 21AHSL42AU RCSL A 4821A 42 500 12 5 30 000 8 8 12 500 3 7...

Page 9: ...4A 49 000 14 4 34 500 10 1 14 500 4 2 12 75 15 00 76 RHKL HM4824 RCSL H 4824A 49 500 14 5 34 900 10 2 14 600 4 3 12 45 15 00 76 RHLL HM4824 RCSL H 4824A 49 000 14 4 34 500 10 1 14 500 4 2 12 75 15 00...

Page 10: ...0 7 2 17 500 5 1 7 100 2 1 12 50 14 00 14 00 72 RCFL A 2417A RGPR 05 BMK 24 600 7 2 17 400 5 1 7 200 2 1 12 15 14 00 72 RCFL A 2417A RGPR 07 AMK 24 600 7 2 17 500 5 1 7 100 2 1 12 40 14 00 72 RCFL H 2...

Page 11: ...07 AMK 30 000 8 8 22 200 6 5 7 800 2 3 12 25 14 00 14 00 73 RCFL H 3621A RGPR 07 BRQ 30 200 8 8 22 350 6 5 7 850 2 3 12 65 14 00 73 21AHBL36HM RCHL 36A1 29 000 8 5 20 850 6 1 8 150 2 4 12 25 14 00 73...

Page 12: ...0 7 4 11 200 3 3 10 75 13 00 14 00 73 RCHL 36A1 RGPR 07 AMK 36 800 10 8 25 700 7 5 11 100 3 3 11 15 13 00 73 RCHL 36A1 RGPR 07 BRQ 37 200 10 9 26 050 7 6 11 150 3 3 11 55 14 00 73 RCHL 36A1 RGPR 10 BR...

Page 13: ...RCFL H 4821A RGGD 09 ZCM 43 000 12 6 30 600 9 0 12 400 3 6 11 90 14 00 76 RCFL H 4821A RGGD 10 ZCM 43 000 12 6 30 600 9 0 12 400 3 6 11 95 14 00 76 RCFL H 4821A RGJD 09 ZCM 43 000 12 6 30 600 9 0 12...

Page 14: ...4 200 4 2 12 35 14 00 15 00 76 RCFL A 4824A RGJD 09 ZCM 48 000 14 1 33 950 9 9 14 050 4 1 12 05 14 00 76 RCFL A 4824A RGJD 10 ZCM 48 000 14 1 33 950 9 9 14 050 4 1 12 10 14 00 76 RCFL A 4824A RGJD 12...

Page 15: ...000 17 9 42 900 12 6 18 100 5 3 11 10 13 00 76 RCFL A 6024A 61 000 17 9 42 900 12 6 18 100 5 3 11 10 13 00 76 25AHBL60HM RCHL 60A1 57 000 16 7 38 350 11 2 18 650 5 5 10 75 13 00 76 RBHK 25 RCHL 60A1...

Page 16: ...ps 024JEZ 1 60 208 230 12 8 12 8 58 3 0 6 17 17 20 20 25 25 11 00 1 02 1 1920 906 72 2041 140 63 5 150 68 0 030JEZ 1 60 208 230 14 1 14 1 73 0 8 19 19 25 25 30 30 12 94 1 20 1 2470 1166 94 2665 160 72...

Page 17: ...2 49 14 94 38 11 58 27 8 23 17 5 18 6 1 83 21 2 Ton 1 4 6 35 0 14 4 27 56 17 07 98 29 87 N A N A 25 7 62 N A N A N A N A N A 3 8 9 53 0 0 0 0 0 0 25 7 62 50 15 24 68 20 73 65 19 81 62 18 90 58 17 68 5...

Page 18: ...18 Rheem Manufacturing Company NOTES...

Page 19: ...Rheem Manufacturing Company 19 NOTES...

Page 20: ...g Applicable Terms and Conditions See Your Local Installer or Contact the Manufacturer for a Copy Compressor Ten 10 Years Any Other Part Five 5 Years This five year limited warranty is applicable only...