Model Number Identification

R801T (DF) Series

5

Model Number Identification—Downflow Models

R

80

1

T

A

075

4

17

Z

S

A

Rheem 

80 =

80% AFUE

1 = Single Stage

T =

Constant

Torque

Design Series

A = 1st Design

Input

BTU/HR [kW]

075 =   75,000 [22]
100 = 100,000 [29]
125 = 125,000 [37]

3 = Up to

3 Ton

4 = 2

1

/

2

to

4 Ton

5 = 3

1

/

2

to

5 Ton

Cabinet

Width

17 = 17.5"
21 = 21"

.0

24 = 24.5"

Z = Down

and Zero

Clearance

Downflow

X = Low NO

x

S = Standard

Revision-

Marketing

(A – First Time

Release)

[    ] Designates Metric Conversions

Summary of Contents for R801T DF Series

Page 1: ...orrosion resistance and thermal fatigue reliability Low profile 34 cabinet ideal for space constrained installations Integrated Control board features dip switches for easy system set up QR code for quick access to product information from your smart phone or tablet Constant Torque electrically commutated motor Air Gas Furnaces R801T DF Series A F U E Annual Fuel Utilization Efficiency calculated ...

Page 2: ...s R801T DF Series 2 TABLE OF CONTENTS Standard Optional Equipment 3 Model Features Physical Data Specifications 4 Model Number Identification 5 Dimensional Data 6 Blower Performance Data 7 Accessories 8 Limited Warranty 9 ...

Page 3: ...sensor diagnostics on board twinning fused protection secondary 3rd speed option for continuous fan common heat cool terminal OPTIONAL EQUIPMENT NOTE Furnace is not listed for use with fuels other than natural or L P propane gas The complete terms of limited and other warranties are available at our sales office or through local installer All models can be converted by a qualified Rheem distributo...

Page 4: ... 254 11 x 10 279 x 254 1hp 5spd X 13 746 1hp 5spd X 13 746 10 9 10 9 MED HIGH MED HIGH HIGH HIGH 2000 944 2000 944 0 5 0 12 0 5 0 12 30 60 17 33 35 65 19 4 36 1 190 87 7 185 85 0 120 54 140 63 80 0 80 0 AFUE Electronic Ignition Modules 80 0 80 0 NOTES All models are 115V 60HZ 1Ø Gas connection size for all models is 1 2 N P T In accordance with D O E test procedures See Conversion Kit Index Form f...

Page 5: ...AFUE 1 Single Stage T Constant Torque Design Series A 1st Design Input BTU HR kW 075 75 000 22 100 100 000 29 125 125 000 37 3 Up to 3 Ton 4 21 2 to 4 Ton 5 31 2 to 5 Ton Cabinet Width 17 17 5 21 21 0 24 24 5 Z Down and Zero Clearance Downflow X Low NOx S Standard Revision Marketing A First Time Release Designates Metric Conversions ...

Page 6: ...120 54 4 100 21 533 1927 32 504 137 8 352 201 8 511 0 0 0 1 25 3 76 6 152 120 54 4 125 241 2 622 2311 32 593 155 8 397 235 8 600 0 0 0 1 25 3 76 6 152 140 63 5 MODEL R801T DOWNFLOW SERIES B C D E Dimensional Data NOTES May require a 3 76 mm to 4 102 mm or 3 76 mm to 5 127 mm adapter May be 0 0 mm with type B vent May be 1 25 mm with type B vent Furnaces must be vented in accordance with the Nation...

Page 7: ...2 1105 1358 1564 1877 2083 1093 1317 1529 1840 2054 931 1227 1451 1767 1977 901 1196 1416 1706 1945 791 1093 1340 1636 1874 801TA100521ZSA 1 748 11 x 10 279 x 254 Low Med Lo Med Med Hi High 1240 1405 1600 1903 2072 1120 1364 1561 1877 2028 1073 1317 1526 1833 2006 974 1232 1445 1766 1940 917 1181 1403 1711 1908 799 1083 1325 1631 1840 801TA125524ZSA 1 748 11 x 10 279 x 254 Low Med Lo Med Med Hi Hi...

Page 8: ...DE INSTRUCTIONS Caution Always follow National Fuel Gas Code NFGC guidelines when converting for high altitudes High altitude option codes are not required for these models However the burner orifice size needs to be recalculated and verified at elevations above 2000 ft See Installation Instructions for more information NOTE For Canadian installations only an optional derate manifold gas pressure ...

Page 9: ...within the applicable period stated in accordance with the terms of the limited warranty For complete details of the Limited and Conditional Warranties including applicable terms and conditions contact your local contractor or the Manufacturer for a copy of the product warranty certificate Heat Exchanger Twenty 20 Years Conditional Parts Registration Required Ten 10 Years ...