16
Installing the water heater
Installations requiring less than one (1) foot of vertical pipe before the first elbow, subtract six
(6) feet from the maximum vent length.
Less than 1 ft.
vertical pipe
before first
elbow
Minimum Vent Restrictor
Vent Pipe
Mesh
Vent Restrictor
Vent Terminal
Install the vent restrictor only at the minimum vent lengths listed on page 15.
Additional Venting Requirements
Additional PVC Fittings Considerations
DO NOT
Use
Short Sweep 90° Elbow
Long Sweep 90° Elbow
Best
Good
Standard 90° Elbow
DO NOT
use the vent restrictor for any other vent lengths.