background image

Rheem Heating, Cooling and Water Heating

3

R

G

T

C

06E

A

M

E

S

Rheem

Gas

Furnace

Downflow/

Horizontal

Condensing

Gas Furnace

Design

Series

Heating Input 

Designation

Variations

A

= Std.

B

= Wide

Cabinet

Blower Size

M

= 11 x 7

[279 x 178 mm]

R

= 11 x 10

[279 x 254 mm]

Z

= 12 x 11

[305 x 279 mm]

Heat/Cool

Designation

E

= 1100-1300 CFM

[519-613.5 L/s]

G

= 1500-1700 CFM

[707.9-802.3 L/s]

J

= 1900-2100 CFM

[896.7-991.1 L/s]

Fuel Code

S

= U.S. and

Canadian Natural
Gas

Electric

Ignition

04E
06E
07E
09E
10E

Input

BTU/HR

45,000 [13 kW]
60,000 [17.6 kW]
75,000 [20.5 kW]
90,000 [26.4 kW]

105,000 [30.7 kW]

MODEL NUMBERS

RGTC-04EMAES

RGTC-06EMAES

RGTC-07ERBGS

RGTC-09EZAJS

RGTC-10ERBJS

INPUT-BTU/HR [kW] 

45,000 [13.19]

60,000 [17.58]

75,000 [21.98]

90,000 [26.38]

105,000 [30.77]

HEATING CAPACITY BTU/HR [kW]

41,000 [12.02]

56,000 [16.41]

69,000 [20.22]

84,000 [24.62]

97,000 [28.43]

HIGH ALTITUDE INPUT [kW] 

40,500 [11.87]

54,000 [15.83]

67,500 [19.78]

81,000 [23.74]

94,500 [27.70]

HIGH ALTITUDE OUTPUT 
CAPACITY [kW] 

37,000 [10.84]

50,400 [14.77]

63,000 [18.46]

75,000 [21.98]

87,500 [25.64]

BLOWER (D x W) [mm]

11 x 7 [279 x 178]

11 x 7 [279 x 178]

11 x 10 [279 x 254]

12 x 11 [305 x 279]

11 x 10 [279 x 254]

MOTOR H.P. [W]
SPEEDS-TYPE

1

/

2

[373]-4-PSC

1

/

2

[373]-4-PSC

1

/

2

[373]-4-PSC

3

/

4

[559]-4-PSC

3

/

4

[559]-4-PSC

MOTOR FULL LOAD AMPS

6.8

6.8

6.8

9.5

9.5

HEATING SPEED

MED-LOW

MED-HI

MED-HI

MED-HI

MED-HI

COOLING SPEED

HIGH

HIGH

HIGH

HIGH

HIGH

HEAT EXT. STATIC PRESSURE
(IN. W.C.) [kPa]

.10 [.025]

.12 [.029]

.12 [.029]

.15 [.037]

.20 [.049]

RATED EXT. STATIC PRESSURE
(IN. W.C.) [kPa]

.50 [.124]

.50 [.124]

.50 [.124]

.50 [.124]

.50 [.124]

HEATING CFM @ .2" W.C. 
E.S.P. [L/s]

866 [409]

1122 [530]

1516 [716]

1698 [802]

1812 [856]

COOLING CFM @ .5"  W.C. 
E.S.P. [L/s]

1220 [576]

1242 [586]

1559 [736]

1850 [873]

1977 [934]

TEMPERATURE RISE RANGE 
°F [°C]

30-60 [16.7-33.3]

30-60 [16.7-33.3]

30-60 [16.7-33.3]

30-60 [16.7-33.3]

35-65 [19.4-36.1]

APPROX. SHIPPING WEIGHT
(LBS.) [kg]

123

126

137

148

160

AFUE 

95.0%

95.0%

95.0%

95.0%

95.0%

STANDARD FILTER [mm]

(2) 12" x 20"

[305 x 508]

(2) 12" x 20"

[305 x 508]

(2) 12" x 20"

[305 x 508]

(2) 12" x 20"

[305 x 508]

(2) 14" x 20"

[356 x 508]

BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE
FROM YOUR RETAILER.

PHYSICAL DATA AND SPECIFICATIONS
DOWNFLOW/HORIZONTAL MODELS 

U.S. and Canadian Models

NOTES: All models are 115V, 60HZ, 1

ø.

Gas connection size for all models is 

1

/

2

" [13 mm] N.P.T.

See Conversion Kit Index Form for high altitude derate.

➁ 

Canadian installations only.

In accordance with D.O.E. test procedures.

MODEL IDENTIFICATION

[

] Designates Metric Conversions

GENERAL TERMS OF LIMITED WARRANTY

Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable
period stated, in accordance with the terms of the limited 
warranty.

For Complete Details of the Limited Warranty, Including Applicable Terms
and Conditions, See Your Local Installer or Contact the Manufacturer for
a Copy.

Primary and Secondary Heat Exchanger.......Limited Lifetime
Conditional Parts (Registration Required) .......Ten (10) Years

Summary of Contents for CLASSIC 90 PLUS

Page 1: ...for optional accessories Top electrical connections left or right gas and conden sate drainage connections on downflow models Condensate drain for horizontal application provided standard Integrated c...

Page 2: ...cooling applications transformer direct drive multi speed blower motor Please note a thermostat is not included as standard equipment OPTIONAL EQUIPMENT NOTE Furnace is not listed for use with fuels...

Page 3: ...XT STATIC PRESSURE IN W C kPa 10 025 12 029 12 029 15 037 20 049 RATED EXT STATIC PRESSURE IN W C kPa 50 124 50 124 50 124 50 124 50 124 HEATING CFM 2 W C E S P L s 866 409 1122 530 1516 716 1698 802...

Page 4: ...D E F LEFT SIDE MINIMUM CLEARANCE IN mm SHIP WGTS kg RIGHT SIDE BACK TOP FRONT VENT 04 171 2 445 1611 32 415 155 8 397 2 51 165 8 422 137 8 352 0 0 0 1 25 2 51 0 123 56 06 171 2 445 1611 32 415 155 8...

Page 5: ...Horizontal furnace may be installed for horizontal left hand air supply ONLY The condensate trap provided for horizontal application must be installed in the field beneath the unit as directed in the...

Page 6: ...8 632 1555 734 1743 823 1097 518 1309 618 1516 716 1696 801 1068 504 1280 604 1477 698 1649 779 1036 489 1253 592 1440 680 1604 757 1003 473 1225 579 1402 662 1559 736 963 455 1185 560 1349 637 1501 7...

Page 7: ...Rheem Heating Cooling and Water Heating 7 NOTES...

Page 8: ...ate Provincial and Local codes regulations and practices Rheem Heating Cooling and Water Heating P O Box 17010 Fort Smith AR 72917 In keeping with its policy of continuous progress and product improve...

Reviews: