Rheem Heating, Cooling and Water Heating

STANDARD EQUIPMENT

Completely assembled and wired; heat exchanger; primary: 409 and aluminized
409 stainless steel, secondary: 29-4C stainless steel; induced draft; pressure
switch; redundant main gas control; blower compartment door safety switch;
solid state time on/off blower control; limit controls; manual shut-off valve;
100% safety lock out; cool fan off delay; field selectable heat fan off delay; one
hour automatic retry; power and self-test diagnostics; flame sense current
diagnostics; electronic air cleaner connections; twinning (built-in) features;
humidifier connections; humidifier on/off delay; low speed continuous fan
option; single speed option for heating and cooling applications; transformer;
direct drive, multi-speed blower motor. (Please note: a thermostat is not
included as standard equipment.)

OPTIONAL EQUIPMENT

NOTE: Furnace is not listed for use with fuels other than natural or L.P. 

(propane) gas.

All models can be converted by a qualified distributor or local service dealer to
use L.P. (propane) gas without changing burners. Factory approved kits must 
be used to convert from natural to L.P. (propane) gas and may be ordered as
optional accessories from a parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form.

WARNING

THIS FURNACE IS NOT APPROVED

OR RECOMMENDED

FOR USE IN MOBILE HOMES

CLASSIC

®

90 PLUS HIGH EFFICIENCY

DOWNFLOW/HORIZONTAL
GAS FURNACE

PRIMARY AND SECONDARY
HEAT EXCHANGER

REMOTE SENSOR

DIRECT SPARK IGNITION

IN-SHOT BURNERS

PRESSURE SWITCH

DRAFT INDUCER

INTEGRATED
FURNACE
CONTROL

GAS VALVE AND
MANIFOLD

FUSE PROTECTION

Summary of Contents for CLASSIC 90 PLUS

Page 1: ...for optional accessories Top electrical connections left or right gas and conden sate drainage connections on downflow models Condensate drain for horizontal application provided standard Integrated c...

Page 2: ...cooling applications transformer direct drive multi speed blower motor Please note a thermostat is not included as standard equipment OPTIONAL EQUIPMENT NOTE Furnace is not listed for use with fuels...

Page 3: ...XT STATIC PRESSURE IN W C kPa 10 025 12 029 12 029 15 037 20 049 RATED EXT STATIC PRESSURE IN W C kPa 50 124 50 124 50 124 50 124 50 124 HEATING CFM 2 W C E S P L s 866 409 1122 530 1516 716 1698 802...

Page 4: ...D E F LEFT SIDE MINIMUM CLEARANCE IN mm SHIP WGTS kg RIGHT SIDE BACK TOP FRONT VENT 04 171 2 445 1611 32 415 155 8 397 2 51 165 8 422 137 8 352 0 0 0 1 25 2 51 0 123 56 06 171 2 445 1611 32 415 155 8...

Page 5: ...Horizontal furnace may be installed for horizontal left hand air supply ONLY The condensate trap provided for horizontal application must be installed in the field beneath the unit as directed in the...

Page 6: ...8 632 1555 734 1743 823 1097 518 1309 618 1516 716 1696 801 1068 504 1280 604 1477 698 1649 779 1036 489 1253 592 1440 680 1604 757 1003 473 1225 579 1402 662 1559 736 963 455 1185 560 1349 637 1501 7...

Page 7: ...Rheem Heating Cooling and Water Heating 7 NOTES...

Page 8: ...ate Provincial and Local codes regulations and practices Rheem Heating Cooling and Water Heating P O Box 17010 Fort Smith AR 72917 In keeping with its policy of continuous progress and product improve...

Reviews: